10 · Troubleshooting

Troubleshooting decision tree: symptom → quick check → action

A symptom-oriented debugging guide for the rbamp component in ESPHome. Every entry follows the same shape: what you see in the log, what it means, how to diagnose it, and a concrete fix.

Contents:

  1. I²C / hardware
  2. Data quality
  3. Energy and persistence
  4. Home Assistant integration
  5. Build and toolchain
  6. Identity / Capability / Error (v1.3)

1. I²C / hardware

Probe failed at 0x50 — no response

What you see in the log:

plaintext
[E][rbamp:xxx]: Probe failed at 0x50 — no response. Check wiring/address.
[E][component:xxx]: Component rbamp was marked as failed.

The component then calls mark_failed() and stops further update() calls. All bound sensors stay "Unknown" in Home Assistant.

What it means:

The ESP32 sent the address phase to 0x50 (or another address from address:) and received no ACK. The module is either absent, unpowered, or on a different address.

How to diagnose:

  1. Confirm that scan: true is set in the i2c: YAML block. Reboot the ESP32 and watch for:

    [I][i2c.arduino:069]: Found i2c device at address 0x50

    If the scan found the device, the address: key in your rbamp: block is wrong — update it.

  2. Measure 3.3 V on the module's VCC pin with a multimeter. Zero or < 3.0 V means power is missing or marginal.

  3. Check the continuity of SDA and SCL from the ESP32 GPIO to the module connector. A missing or swapped wire is the most common cause on fresh builds.

  4. Check the pull-up resistors on SDA and SCL (4.7 kΩ to 3.3 V). Without pull-ups the bus sits low and every address phase looks like a NACK.

  5. If you recently performed an address change (the new_address: key), the module may now be on the new address. Add scan: true, find the device, update address: accordingly, and remove new_address:.

Fix: correct the wiring / power, and update address: if the module moved. If the module does not respond after an address change, see "Address changed but module not responding" below.


RT block not ready — publish skipped

What you see:

plaintext
[D][rbamp:xxx]: RT block not ready (STATUS=0x00) — skipping live publish

What it means: the status register reported that the module is not ready. This happens when the module has not yet committed its first instantaneous-values block after startup, is mid flash-write, or is in a soft reset.

How to diagnose:

  1. If the entry appears once at boot (in the first 30 s after power-up) and then disappears, this is normal. The module needs one commit cycle (~200 ms) to set the READY bit after power-up. The startup latch in setup() also produces one skipped cycle.

  2. If the message streams continuously after warm-up, the module may be stuck. Check for repeated ct_model: / ct_models: entries (for example, a key left in the YAML that is written on every boot, producing a permanent flash-write window).

  3. If the message appears occasionally (once every few cycles), this is normal variability tied to NACKs. The retry loop catches most transients; sometimes the status read still fails, which triggers this DEBUG entry.

Fix:

  • Warm-up skips at boot are expected; wait two full update_interval cycles.
  • If ct_model: / ct_models: is set in the YAML, leave it: on each boot the repeated write is idempotent (the module does not write if the value is already in flash). If the warm-up skips bother you, comment out the key after a successful first run.
  • If the module stays not-ready for 60+ s, power-cycle the module (not the ESP32) for a clean cold start.

"rbamp took a long time for an operation (XXX ms)"

What you see:

plaintext
[W][component:522]: rbamp took a long time for an operation (406 ms), max is 30 ms

What it means: this warning fires when any component's update() exceeds the ESPHome cooperative scheduler's default 30 ms budget. For the rbamp component this is expected and harmless.

On v1.3 firmware, READ auto-increment is supported for the instantaneous-values block (the contiguous range covering U / I / P / PF / Q for all declared channels). The component issues a single burst read for that block — one address phase followed by ~36 data bytes — which costs ≈ 8–10 ms of wire time at 50 kHz. WRITE auto-increment is not supported, so per-register writes (CT model staging, sensor class, address commit) still go byte-at-a-time. If the burst read fails (NACK partway through, capability bit not set on legacy firmware), the component falls back to per-register reads (4 transactions per float, up to 36 transactions ≈ 90 ms at 50 kHz). With the per-byte retry triple (up to 3 × 5 ms gap on a NACK-heavy cycle) the worst-case fallback path is normally 300–450 ms — which is what produces this warning when it appears.

The latch-settle (set_timeout("rbamp_period", 50, ...)) is non-blockingupdate() yields control to the scheduler while the 50 ms elapse. The warning reflects the wall-clock time of the whole blocking instantaneous-values read, not WiFi or API starvation.

No user action is required. The warning is cosmetic; HA sensors update correctly. On healthy v1.3 modules the burst-read path normally stays under 30 ms and the warning does not fire at all.

If the warning fires every cycle: the bus is forcing the per-register fallback (legacy firmware without the READ-burst capability, or marginal pull-ups producing mid-burst NACKs). Check the firmware version (Firmware version: 0x04 in the boot log = v1.3) and the pull-up topology (single 4.7 kΩ pair to clean 3.3 V).


Failed to read the period snapshot

What you see:

plaintext
[W][rbamp:xxx]: Failed to read PERIOD_AVG_P[0]
[W][rbamp:xxx]: Failed to read PERIOD_AVG_P[1]

What it means: after the latch command and the 50 ms wait, the component could not read the period-average power register for channel N after three retries. The energy accumulator for that channel is not updated in this cycle.

The most common causes:

  1. Flash-write blackout. The module is writing a CT model (triggered by ct_model: or ct_models: at boot) or saving a new address. The window is ~700 ms; if the 50 ms latch-settle lands in it, the read times out.
  2. Missed latch under heavy polling. Under heavy back-to-back I²C polling the module side may miss a latch. The snapshot stays empty, but the valid flag will be 0 — the component skips integration with the message "Period snapshot not yet valid; keeping previous integration window". The warning fires only when the valid flag is set but the register read still failed.
  3. Transient NACK exhaustion. All three retries on at least one of the float's four bytes failed. Rare at 50 kHz (< 1% of cycles); more frequent at 100 kHz.

What happens to the energy: on a warning, last_latch_ms_ is not updated. On the next successful cycle, dt_ms covers both the missed window and the new one — energy recovers, assuming a roughly stable load over the interval. This is an acceptable small inaccuracy.

Fix:

  • Remove address-change keys (new_address:) from the YAML after the first successful boot.
  • If the warning fires more than once an hour, check the bus speed (50kHz is recommended) and the pull-up resistors (4.7 kΩ).
  • If the warning fires on every cycle, check for a conflict with another device on the bus.

Address changed but module not responding

What you see:

plaintext
[E][rbamp:xxx]: Address change applied but slave not responding at 0x51 —
    check wiring and try power-cycling the rbAmp.
[E][component:xxx]: Component rbamp was marked as failed.

What it means: the address-change flow ran through all steps (write the new address, save to flash, soft reset, switch the component's internal I²C address), but the module did not respond on the new address on the first check.

Possible causes:

  1. The address was written and saved, but the module entered a bad state (flash parameter corruption, a power glitch during the 700 ms write window).
  2. The module was not in factory-provisioning mode at the time of the attempt. The mode-status read may itself have failed (NACK), in which case the component performs the write speculatively, with a warning in the log.
  3. A wiring problem that existed before the address change (the old-address probe only succeeded by coincidence on one of the three retries).

Recovery procedure:

  1. The module is on an unknown address. Use a test YAML with i2c: scan: true and a power cycle — find which address the module responds on.
  2. If the module is found on the new address (for example 0x51), update the YAML to address: 0x51, remove new_address:, and reflash. The next boot will be clean.
  3. If the module does not respond on any address, the flash write may have corrupted the parameters. Recovery requires physical intervention: consult the module documentation or your supplier.

Background: the address-change flow on v1.3 firmware is a two-phase commit — the master writes the new address into a staging register, then issues CMD_COMMIT_ADDR to make it persistent. The 700 ms write window is the flash-erase + program of the user-config page. See 09 · API reference.


i2c_master hung — ESP32 boot-loop or RT block never publishes

What you see:

plaintext
[I][i2c.idf:xxx]: Performing I2C bus reset...
[E][i2c.idf:xxx]: i2c_master_send_buf failed: ESP_ERR_TIMEOUT
[E][rbamp:xxx]: Probe failed at 0x50 — no response. Check wiring/address.
[E][component:xxx]: Component rbamp was marked as failed.

In the worst case, a task watchdog timeout reboots the ESP32 after several minutes of soak (under load, not at bring-up). It can look like "the module worked for an hour and then stopped".

What it means: the ESP-IDF v5 i2c_master driver has a known hazard: on a marginal bus (slow rise time, weak pull-up, EMI burst) the internal i2c_ll_is_bus_busy infinite-spins, waiting for a STOP condition that never arrives. In ESPHome 2025.x this spin can eat the app-WDT budget and trigger a reboot. This is a canon ESP-IDF problem, not rbAmp-specific.

Three-layer mitigation (all active in the component by default, plus hardware recommendations):

  1. Software: the built-in NACK discipline — 50 kHz by default + 3× per-byte retry with a 5 ms gap + the IP-009 sanity filter std::isfinite(). Already in the component since v0.2+. Do not disable frequency: 50kHz until the stop-handler hardening fix ships in the firmware.
  2. Hardware: an external 4.7 kΩ pull-up on SDA + SCL (a single external pull-up pair, with the in-module jumpers cut — see §Multi-module bus). The ESP32 internal pull-ups (~50 kΩ) are weak — on a long bus or with a marginal supply they are not enough. 4.7 kΩ pull-ups to clean 3.3 V are mandatory for a production deployment.
  3. Hardware: do not hold the debugger / OTA reset asserted during I²C transactions. A RESET asserted in the middle of a transaction leaves the bus hung (the slave continues to drive SDA), which is exactly what provokes the bus-busy infinite-spin.

Hang rate validated on the bench (Fix-A fleet, 24-hour soak):

Layer Hang rate Note
Software only (no external pull-up) ~1× per 10 minutes the bridge-WDT fires and recovers via reset, but Wh loses a window
Software + external 4.7kΩ pull-up ~1× per 24 hours EMI-burst edge case; auto-recovery
Software + external pull-up + clean reset 0 hangs over 24h soak production target

Severity = measurement-time (full-duration soak), not bring-up. At bring-up the NACK discipline catches 99%+ via the retry triple — real hangs only begin after hours of clean soak. For the full discipline reference, see 09 · API reference.

If recovery fails: as a last resort, configure wdt: (esphome core) with an increased app_wdt_timeout_seconds: (default 5 s; set 10–15 s). This buys time for component recovery without a reboot.


2. Data quality

Voltage jumps around — 228 V / 502 V / 1.96 V intermixed

What you see:

plaintext
[D][sensor:xxx]: 'Mains Voltage': Sending state 502.730 V
[D][sensor:xxx]: 'Mains Voltage': Sending state 1.964 V
[D][sensor:xxx]: 'Mains Voltage': Sending state 228.365 V
[D][sensor:xxx]: 'Mains Voltage': Sending state 502.730 V

In Home Assistant the voltage graph is a sawtooth between ~228 V, ~2 V, and ~503 V. Current may simultaneously show 0 A or −2 A.

What it means: "ghost" values are surfacing from a buffer leak in the ESP-IDF i2c_master driver under NACK conditions at 100 kHz. This should be eliminated by the default configuration of the current component version. If the symptom appears:

  • The i2c: block has frequency: 100kHz — change it to 50kHz.
  • The component version is older than 2026-05-24 — update it.

Fix:

yaml
i2c:
  sda: GPIO21
  scl: GPIO22
  frequency: 50kHz   # required for reliable operation
  scan: true

For more on the NACK-discipline mechanism (50 kHz default + per-byte retry + sanity filter for NaN/Inf), see 09 · API reference.

Compatibility with framework: type: — the NACK ghost-value problem manifests only under the ESP-IDF i2c_master driver. On framework: type: arduino (the default), the Arduino-framework Wire stack is used, which behaves differently under NACK and does not reproduce this symptom. This means:

  • If the YAML has esp32: framework: type: arduino, you can in theory keep frequency: 100kHz without visible ghost spikes, but the component's per-byte retry loop still runs on top of Wire and the periodic NACKs at 100 kHz remain — just without the chilling ghosts. For stable HA graphs we recommend 50 kHz regardless of framework.
  • If the YAML has esp32: framework: type: esp-idf, then frequency: 50kHz is mandatory. This is the configuration in which the i2c_master driver shows the ghost symptom most vividly.

The component itself does not choose the framework — it runs on top of both. This is purely a decision in your YAML.


Current is permanently 0 A under load

What you see:

plaintext
[D][sensor:xxx]: 'Mains Current': Sending state 0.000 A

Power is 0 W, energy does not grow, but voltage reads correctly (for example 228 V).

What it means: one of two typical causes:

Cause 1 — ct_model: is not set or does not match the physical clamp. On firmware v1.2+ the module uses the factory coefficients for the model selected in the YAML. If ct_model: is unset, or set to, say, SCT_013_050 with a real SCT-013-005, the measurement range is so much wider than the physical signal that the AC-ADC resolution yields zero counts.

Cause 2 — the clamp is installed incorrectly on the conductor (see polarity in 03_sensor_selection.md and clamping around only one conductor).

How to diagnose:

  1. Confirm the clamp is physically installed on a current-carrying conductor and that the conductor really carries current (use a clamp meter as a reference, if you have one).
  2. Open the YAML and check that ct_model: (or ct_models: for UI3) matches the physical clamp model.
  3. If ct_model: is set on firmware v1.2+ but sensor_class: is omitted or set to a value other than SCT_013, the module refuses the model write. The boot log shows a warning pointing to the missing precondition.

Fix:

yaml
rbamp:
  id: meter1
  sensor_class: SCT_013       # default; required on v1.2+ before ct_model
  ct_model: SCT_013_005       # match the physical clamp

After boot the module writes the model to flash once (~700 ms) and loads the factory coefficients. The next instantaneous-values publish already gives correct current.

Small-current measurement accuracy on UI2 / UI3 — the dual-CT pattern. If you want high resolution on small loads (lighting, standby) and a wide range for peaks (kettle, washing machine) at the same time, use two current channels on the same phase simultaneously with different clamps:

yaml
rbamp:
  id: home_meter
  sensor_class: SCT_013
  ct_models: [SCT_013_005, SCT_013_030, SCT_013_050]
  # CH0 — SCT-013-005 for resolving idle loads (~5..50 W)
  # CH1 — SCT-013-030 for the main household load (~50..7000 W)
  # CH2 — SCT-013-050 for the peak (EV-charging headroom up to 11.5 kW)
  # NOTE v1.3: SCT_013_100 reserved; for peaks > 50A — several SCT_013_050 in parallel

All three clamps clamp around the same L-phase conductor. SCT-013-005 gives ~10× better resolution on small currents than SCT-013-030, but saturates at ~5 A. SCT-013-030 covers the "middle" of the useful range; SCT-013-050 catches peak surges up to ~11.5 kW without saturating. On the HA side, a template sensor selects the "active" measurement by threshold:

yaml
# configuration.yaml — select the active channel by range
template:
  - sensor:
      - name: "Mains Current (active)"
        unit_of_measurement: "A"
        device_class: current
        state_class: measurement
        state: >
          {% set i0 = states('sensor.rbamp_ch0_current') | float(0) %}
          {% set i1 = states('sensor.rbamp_ch1_current') | float(0) %}
          {% set i2 = states('sensor.rbamp_ch2_current') | float(0) %}
          {% if i2 > 25 %}{{ i2 }}
          {% elif i1 > 4 %}{{ i1 }}
          {% else %}{{ i0 }}
          {% endif %}

This fully covers the 5 mA..100 A range with ~1 mA resolution on small loads. Trade-off: three CT clamps on one conductor are physically bulky, and each occupies one module channel (on UI3 that is the whole module). For most deployments a single clamp with a rating matched to the load covers 99% of scenarios — the dual/triple-CT pattern is needed only when wide dynamic range is required.


Period snapshot not valid — energy does not grow

What you see:

plaintext
[D][rbamp:xxx]: Period snapshot not yet valid; keeping previous integration window

The energy sensor in Home Assistant shows a constant (or stays at 0 Wh after boot), even though power reads correctly.

What it means: the period-snapshot valid flag was 0 when the component checked it 50 ms after the latch command. The module has not yet committed a valid period snapshot.

Normal causes:

  1. First latch after boot. The startup latch in setup() always discards its result — the module accumulator is reset on the first latch command. The second latch (one update_interval after boot) is the first one that integrates. Energy starts accumulating after the first full update_interval from boot.
  2. Module cold start. The module needs at least one ~200 ms commit cycle for any data in the period accumulator. If the first latch falls earlier, the valid flag is 0.
  3. Missed latch under heavy polling. Under heavy I²C load the module side may miss a latch. The snapshot stays empty; the next latch should succeed.

If the entry fires on every update() cycle indefinitely (not just the first two), the module may be in a state where the period accumulator never commits. Power-cycling the module clears this state.


3. Energy and persistence

energy_total reset to 0 after a reboot

What you see in the HA Energy dashboard: a sharp drop to 0 Wh, then normal accumulation from 0. The old Wh history is preserved in HA long-term statistics, but the "current meter reading" looks reset.

What it means: restoring from NVS found no data or loaded invalid data. Possible causes:

  1. NVS layout version bump. The NVS key is derived from the component ID, XORed with a layout-version constant. If the structure layout changed (with a component upgrade), the NVS slot key changes and the old data is no longer found. Restoration silently starts from 0.
  2. NVS fragmentation or corruption. The ESP32 NVS partition uses flash wear-leveling. On very old deployments or after many flashes, fragmentation can cause a save to fail. The log shows: [W][rbamp:xxx]: Failed to save Wh totals to NVS — will retry next cycle.
  3. Partition layout change. Flashing a new partitions.csv that changes the size or position of the nvs partition invalidates all saved values.
  4. First boot after a factory reset or full flash erase. Expected: NVS is empty, the accumulator starts from 0.

How to diagnose:

Look in the boot log for:

plaintext
[C][rbamp:xxx]: No saved energy state — starting from 0 Wh

If present, restoration found nothing. Also:

plaintext
[C][rbamp:xxx]: Restored Wh from NVS: total[0.310, 0.000, 0.000] export[...]

If the restored value is noticeably lower than expected, the last 5-minute NVS save may have been skipped (worst-case loss: ≈ 5 Wh at an average of 60 W).

Fix:

  • On a component upgrade that changes the NVS layout, old totals do not restore automatically. HA long-term statistics keep the history even if the "current reading" zeros out.
  • To preserve Wh through a forced NVS wipe, read the current sensor values in HA Developer Tools before the wipe and record them. There is no way to inject a starting value into the component.

Raw chip REG_PERIOD_LATCH_MS reads ~27% lower than the real period time (v1.3 diagnostic)

What you see (if you read raw registers via lambda: or via direct i2c-debug):

plaintext
[D][lambda:xxx]: REG_PERIOD_LATCH_MS = 14860  (chip-side period accumulator)
[D][lambda:xxx]: t_master_dt          = 20003 ms (millis() between latches)

That is, the chip-side counter shows ~14.9 s while the wall-clock millis() shows ~20.0 s. The ~26–27% difference is expected, not a bug.

What it means: the chip-side period counter (REG_PERIOD_LATCH_MS 0xEC and REG_PERIOD_MS_FW 0xCA) is counted on the microcontroller's SysTick timer, which suffers from SysTick starvation under full ISR load (DMA + I²C + period commit + zero-cross detector). This problem was measured on the bench: the chip counter reads ~26–27% lower than the real wall-clock time.

Canon L9: the ESPHome component (like all sister libraries — esp-idf / arduino / python) does NOT use the chip-side counter for energy integration. Wh accumulation is computed on the master wall-clock via millis() (= ESP32 esp_timer_get_time()):

cpp
// finish_latch_phase_() in src/rbamp_period.cpp:
uint32_t t_now = millis();
uint32_t dt_ms = t_now - last_latch_ms_;
e_wh[ch] += avg_p_w[ch] * (double)dt_ms / 3'600'000.0;
last_latch_ms_ = t_now;

Wh is monotonic, with billing-grade accuracy. Validated on the bench: with master_dt/wall=0.999 vs latch_ms/wall=0.743, energy rel_err = 0.0000%.

Anti-revert callout: if you fork the component and want to "optimize" it by switching integration to the chip-side REG_PERIOD_LATCH_MSDO NOT DO THIS. It will give a ~27% Wh undercount. The anti-revert comment is inlined in finish_latch_phase_ and in rbamp_const.h.

User-side diagnostics: REG_PERIOD_LATCH_MS remains accessible via a raw register read (lambda access to the internal RbAmpComponent::read_reg16_(0xEC)). This is diagnostic only — for checking chip health, not for billing.


Energy in HA does not match a reference meter

What you see: the energy sensor in HA reads noticeably lower (for example 10–20%) than a reference smart meter or the utility meter over the same period.

What it means: the component uses the ESP32-side millis() interval between latch commands as the integration time, not the module's timer. That is, the module's clock drift does not affect the accuracy of the energy accumulated in the component.

If the energy reads low, look among these:

  1. Load character. The period-average power register is genuinely time-averaged power over a closed period, not an instantaneous value. A pulsed load (motor, compressor) with a short on-time within the 60-second period averages below its peak power.
  2. Clamp placement and burden calibration. If the factory CT model (ct_model:) does not match reality, the coefficient ranges will be offset. Check that ct_model: in the YAML matches the physical clamp on the conductor.
  3. BASIC firmware tier. On the BASIC SKU, per-window P samples are clamped to 0 before integration. If the load has a regenerative component (for example a pump motor with back-EMF), BASIC undercounts.

4. Home Assistant integration

HA shows "Unavailable" for all rbamp sensors

What you see in HA: all sensor.rbamp_* entities show "Unavailable".

Causes and fixes:

  1. ESP32 offline. Run esphome logs --device <IP> — if you cannot connect, the ESP32 is offline. Check the WiFi credentials, and the fallback AP if one is configured.
  2. API connection lost. The ESPHome native API (port 6053) may be blocked by a firewall. Check that the ESP32 is reachable by IP:

    ping <esp32-ip>

    If ping succeeds but HA still shows unavailable, the ESPHome integration in HA needs to be removed and re-added (Settings → Integrations → ESPHome → Delete, then re-discover). 3. API encryption key mismatch. If api: encryption: key: is configured in the YAML, the HA integration must know the same key. A mismatch makes HA treat the device as offline. Remove and re-add the integration after updating the key. 4. mDNS does not work in your network topology. If the ESP32 is on a different VLAN from HA, multicast mDNS may not cross the boundary. Add the device by IP manually in the ESPHome integration.


OTA flashing fails

What you see:

plaintext
ERROR Error resolving IP address: ...
# or
ERROR Upload Failed

Common causes:

  1. The IP address changed. The ESP32 got a new DHCP lease. Check the router's DHCP table, find the device by MAC, and assign a static IP, or use the wifi: use_address: YAML key.
  2. The ESP32 is in safe mode. After three failed boots in a row ESPHome enters safe mode (no custom components, only WiFi + OTA). Safe-mode OTA works, but the device runs a stripped-down firmware. The marker in esphome logs:

    [I][safe_mode:xxx]: Entering safe mode

    Force a clean boot: hold the BOOT button on power-up, or add safe_mode: num_attempts: 10 to widen the threshold. 3. Port 3232 (OTA) is blocked. The OTA protocol uses TCP 3232. Check that no firewall rule blocks it between the machine running esphome run (or the HA host) and the ESP32 IP. 4. A large firmware after adding rbamp. The first OTA after adding an external component may exceed the OTA partition size on the default 4 MB ESP32 layout. Check the esphome compile output for binary-size warnings and switch to a layout with a larger OTA partition if needed.


OTA right after new_address: provisioning does not load

Symptom: after a successful first boot with the new_address: key (the log shows Address change SUCCESS, new address 0x51), the next OTA fails with a compile error or a runtime warning address 0x50 NACK.

What happened: the module now lives on the new address (0x51), but the YAML still points to the old one (address: 0x50). On the next update() the component tries 0x50, gets nothing, and logs constant NACKs. The OTA itself does not actually fail here — it is just an adjacent symptom: you see a stream of rbamp errors in esphome logs and conclude the device is broken.

Recovery in 3 steps:

  1. Edit the YAML:

    yaml rbamp: id: meter1 address: 0x51 # new address — set instead of 0x50 # new_address: 0x51 # ← REMOVE this line. Do not comment it out, # delete it entirely, otherwise the component # tries to provision again and logs a warning update_interval: 60s ct_model: SCT_013_030

  2. Run esphome run <yaml> (via the CLI) or Compile + Upload (via the HA Add-on). The node receives the new binary over WiFi OTA.

  3. Open esphome logs and confirm that the dump_config startup message shows the correct address and that update() runs without NACKs.

Rulenew_address: is a one-time provisioning operation. Once the module has moved to the new address and saved it to flash, the key must be removed from the YAML. Otherwise, on every boot the component will try to provision again (on v1.2+ the module ignores the repeated write, but the warning remains in the log and clutters the HA notify).

If the module does not respond on any address after the change, see "Address changed but module not responding" above.


5. Build and toolchain

Compile error: 'esphome/core/component.h' file not found

What you see in VS Code / clangd: red squiggles everywhere in rbamp.h and rbamp.cpp. Popup:

plaintext
'esphome/core/component.h' file not found

What it means: clangd (the C++ IntelliSense in VS Code) does not have access to the ESPHome + PlatformIO include paths. The build system resolves them correctly during esphome compile; clangd does not.

This is not a build error. If esphome compile example/ui1.yaml passes without errors, the code is correct.

If you want to remove the red squiggles: create a .clangd file in the component directory pointing to the generated include paths from the ESPHome build output (.esphome/build/<name>/src/). This is cosmetic and optional.


PlatformIO crashes with 0xC0000001D (EXCEPTION_ILLEGAL_INSTRUCTION)

What you see:

plaintext
Error: Failed to install Python dependencies (exit code: 3221225501)

(0xC0000001D = 3221225501 in decimal)

What it means: PlatformIO 6.1.19+ uses the uv Rust binary to install Python dependencies into its internal penv. On Intel Lunar Lake CPUs (Core Ultra 7 255H and similar) uv crashes with EXCEPTION_ILLEGAL_INSTRUCTION due to an instruction-set incompatibility. This affects the penv_setup.py install step on a fresh PlatformIO install.

Workaround (pre-install all dependencies via pip, bypassing uv):

pwsh
# Step 1: install the ESP32 platform's Python dependencies directly
& "$env:USERPROFILE\.platformio\penv\Scripts\python.exe" -m pip install `
    "littlefs-python>=0.16.0" "fatfs-ng>=0.1.14" "pyyaml>=6.0.2" `
    "rich-click>=1.8.6" "zopfli>=0.2.2" "intelhex>=2.3.0" "rich>=14.0.0" `
    "cryptography>=45.0.3" "certifi>=2025.8.3" "ecdsa>=0.19.1" `
    "bitstring>=4.3.1" "reedsolo>=1.5.3,<1.8" "esp-idf-size>=2.0.0" `
    "esp-coredump>=1.14.0" "pyelftools>=0.32"
# Step 2: bootstrap the nested ESP-IDF venv (see the next entry)
& "$env:USERPROFILE\.platformio\penv\.espidf-5.5.4\Scripts\python.exe" `
    -m ensurepip --default-pip
& "$env:USERPROFILE\.platformio\penv\.espidf-5.5.4\Scripts\python.exe" `
    -m pip install -r `
    "$env:USERPROFILE\.platformio\packages\framework-espidf\tools\requirements\requirements.core.txt"

Once these packages are installed, get_packages_to_install() in penv_setup.py returns empty and the pip install via uv is not called. Subsequent esphome compile runs work normally.

The workaround must be reapplied after a fresh PlatformIO install or after clearing the ~/.platformio cache.


ESP-IDF venv: no module idf_component_manager

What you see:

plaintext
ModuleNotFoundError: No module named 'idf_component_manager'

It appears on the first esphome compile on a machine where PlatformIO downloaded the ESP-IDF framework but did not run the full bootstrap of its requirements.

What it means: the PlatformIO ESP-IDF framework is installed into the nested venv ~/.platformio/penv/.espidf-5.5.4/ (the version number may differ). That venv needs requirements.core.txt from the framework package. When the uv workaround above is applied, step 2 bootstraps pip into the venv and installs the requirements.

If the error appears after applying the uv workaround but step 2 was skipped:

pwsh
# Find the IDF venv (the version number may differ):
ls "$env:USERPROFILE\.platformio\penv\" | Where-Object { $_.Name -like ".espidf-*" }
# Bootstrap pip into the IDF venv:
& "$env:USERPROFILE\.platformio\penv\.espidf-5.5.4\Scripts\python.exe" `
    -m ensurepip --default-pip
# Install the IDF core requirements:
& "$env:USERPROFILE\.platformio\penv\.espidf-5.5.4\Scripts\python.exe" `
    -m pip install -r `
    "$env:USERPROFILE\.platformio\packages\framework-espidf\tools\requirements\requirements.core.txt"

Substitute your own IDF version number for 5.5.4 (check ~/.platformio/penv/).


esphome compile fails: get_object_id_hash not found

What you see:

plaintext
error: 'class esphome::rbamp::RbAmpComponent' has no member named 'get_object_id_hash'

What it means: an old version of rbamp.cpp called this->get_object_id_hash() to seed the NVS slot. This method was removed from PollingComponent in ESPHome 2025.x.

Fix: update the component to the current version. Modern code uses hash generation compatible with ESPHome 2025.x and newer.


ESPHome too old — set_i2c_address not found

What you see:

plaintext
error: 'class esphome::i2c::I2CDevice' has no member named 'set_i2c_address'

What it means: the new_address: address-change flow calls i2c::I2CDevice::set_i2c_address(), added in ESPHome 2023.6.

Fix: update to ESPHome 2023.6 or newer. The HA ESPHome Add-on tracks the current release automatically — the recommended installation path.

sh
# If using a local Python venv:
pip install --upgrade esphome

6. Identity / Capability / Error (v1.3)

This section explains what the individual values of the identity entities (a template text_sensor via lambda:), the capability bitmap, and the REG_ERROR codes added in v1.3 mean.

Identity reads return "UNK" / "UNREADABLE"

What you see (template text_sensor):

yaml
text_sensor:
  - platform: template
    name: "Meter variant"
    lambda: 'return id(my_meter).get_variant_str();'  # → "UNK" in HA
plaintext
[D][rbamp:xxx]: get_variant_str(): REG_HW_VARIANT read failed (NACK) — returning UNK

What it means:

  • "UNK" — the component could not read REG_HW_VARIANT (0x55) after all retries. Causes: the module is on legacy firmware (v1.0–v1.1, before variant detection), or a marginal I²C bus with NACK exhaustion on this particular register.
  • "UNREADABLE" — the read returned a value outside 0x55..0x5A, beyond the range of valid variant codes. This indicates firmware corruption or a raw register collision (for example a stale buffer).

Fix:

  • If the firmware is below v1.2, variant detection is unavailable. The text_sensor still publishes; use a YAML-side hint via topology: or reinitialize via an HA template.
  • If the firmware is v1.3+ and the bus is marginal, see i2c_master hung.

CAPABILITY bitmap = 0x0000

What you see:

yaml
text_sensor:
  - platform: template
    name: "Meter capability"
    lambda: 'return id(my_meter).get_capability_hex();'  # → "0x0000"

What it means: REG_CAPABILITY (0x57) does not exist on this firmware — it reads as 0 (the standard "register not implemented" behavior on rbAmp firmware). This is legacy firmware v1.0–v1.2.

Component behavior: all capability-gated features (fleet GC, two-phase address commit, save_user_config, clear_error) automatically fall back to the legacy path:

  • fleet_gc_enable: true → warning + skip (capability bit not set)
  • new_address: → single-phase fallback, requires factory-provisioning mode
  • clear_error() → vendor opcode fallback (best effort)

Zero regression: existing v0.4.0 deployments keep working without changes to YAML or behavior. This is canon C5 — capability-gated never breaks legacy.

last_error_str() shows "ERR_PARAM" after a ct_model: or sensor_class: change

What you see:

plaintext
[W][rbamp:xxx]: REG_ERROR after CT_MODEL write: 0xFE (DEV_ERR_PARAM)

get_last_error_str()"ERR_PARAM".

What it means: the firmware rejected the written value. The most common triggers:

  1. Code 5 (SCT_013_100) — reserved in v1.3 firmware, not accepted. Replace it with SCT_013_050 or SCT_013_030.
  2. CT model not in the per-class allowed set — for example WIRED_CT_1 with sensor_class: SCT_013. See 03_sensor_selection.md per-class table.
  3. Code 0 (UNSET) — an attempt to clear the CT model via 0. Not supported; use dev.factoryReset() for a full reset.

Recovery: call id(my_meter).write_clear_error(); via a YAML service or via lambda: in on_boot: to clear REG_ERROR + EVENT_FLAGS bit3. After that you can retry with a correct value.

yaml
api:
  services:
    - service: my_meter_clear_error
      then:
        - lambda: 'id(my_meter).write_clear_error();'

EVENT_FLAGS bit3 (ERR_LATCH) — re-latch behavior

What you see: after clear_error(), ~200–300 ms later bit3 in EVENT_FLAGS is set again (sticky re-latch).

What it means: the firmware durable error channel re-latches bit3 after a clear if the original error condition has not been resolved. This is by design — the master may miss the first clear and must not assume the error is gone forever if the parameter is still wrong.

Fix: full recovery requires two steps:

  1. Remove the cause (replace the wrong CT model code, correct the YAML).
  2. write_clear_error() — this call clears both REG_ERROR and EVENT_FLAGS bit3 in one operation.

If bit3 keeps re-latching, the parameter is still wrong; re-read get_last_error_str() to find out exactly what the firmware is rejecting.