10 · Troubleshooting

Troubleshooting decision tree: symptom → quick check → action

This chapter is organized by the symptoms you observe, not by internal error classification. If you're here, something isn't working as it should. Find your symptom in the list below, jump to the matching section, and work through the diagnostic procedure.

Most bench problems fall into three categories:

  1. Bus-level — the module doesn't respond over I²C, reads return NaN or RB_ERR_NACK.
  2. Data-level — the module responds, but the numbers are wrong: zeros, strange values, wrong sign.
  3. Application-level — the link is unstable, the Wh counter diverges, the sketch hangs.

Shortcut for the impatient: the dev.retryExhaustionCount() and dev.sanityRejectCount() counters must be 0 in steady state. If they aren't, jump straight to the "Module doesn't respond over I²C" section below.


Module doesn't respond over I²C

What you observe: dev.begin() returns false with lastError() == RB_ERR_NACK, or runtime reads regularly "leak" RB_ERR_NACK into user code.

Step 1 — Bus scan

First, confirm that the module is even present on the bus:

cpp
#include <Wire.h>
void setup() {
    Serial.begin(115200);
    Wire.begin();
    Serial.println(F("Scanning..."));
    for (uint8_t addr = 0x08; addr <= 0x77; addr++) {
        Wire.beginTransmission(addr);
        if (Wire.endTransmission() == 0) {
            Serial.print(F("Found 0x")); Serial.println(addr, HEX);
        }
    }
}
void loop() {}

Expected output: Found 0x50 (or a different address if you changed it).

If nothing is found — the problem is in the wiring or power:

  • SDA / SCL are not swapped.
  • Both lines have a pull-up to 3.3 V (the module board has built-in 4.7 kΩ pull-ups — no external ones are needed for a single module).
  • The module's power pin actually carries 5 V (4.5–5.5 V) — older board revisions are not tolerant of 3.3 V.
  • No other master (debug probe, another Arduino) is hanging on the same lines.

If the module is found, but at an unexpected address — someone re-addressed it earlier on the bench. Update the constructor argument:

cpp
RbAmp dev(Wire, 0x52);   // address from the bus scan

Step 2 — ESP32 baseline NACK pattern

If the bus scan finds the module, but dev.readVoltage() periodically returns NaN with RB_ERR_NACK — and you're on an ESP32 — this is a documented baseline pattern: the ESP-IDF v5 i2c_master driver has quirks when working with rbAmp on v1.0 firmware.

The mitigation is already built into the library (RBAMP_NACK_RETRY_ATTEMPTS=3 by default on ESP32), but under heavy load the retry budget can run out.

What to do on ESP32:

  1. Lower the bus speed to 50 kHz:

cpp Wire.begin(); Wire.setClock(50000);

  1. Raise the number of retry attempts for a heavy workload:

cpp #define RBAMP_NACK_RETRY_ATTEMPTS 5 #include <RbAmp.h>

  1. Monitor the retry-exhaustion counter — it should stay zero in steady state:

cpp if (dev.retryExhaustionCount() > 0) { Serial.print(F("WARN: retry exhausted: ")); Serial.println(dev.retryExhaustionCount()); }

Step 3 — NACKs on non-ESP32 platforms

On AVR / STM32duino / ESP8266 / SAMD / RP2040 there is no baseline NACK pattern — these platforms show a ~0 % NACK rate with rbAmp. The library defaults to RBAMP_NACK_RETRY_ATTEMPTS=1 on them.

If NACKs happen here, look for:

  • High bus capacitance — long wires + many devices. Lower the speed to 100 kHz or shorten the cable.
  • Master contention — the library does not support a multi-master configuration.
  • A floating SCL between transactions — a missing pull-up.

Current reads zero on a working load

What you observe: dev.readCurrent(0) returns 0.000 (or a very small value), even though a real consumer is switched on (a kettle, a lamp, an iron). dev.readPowerFactor(0) may show a strange value (NaN / 0 / ±1) — that's a consequence; the cause is in the current.

Diagnostic procedure

  1. Check that the sensor class and the CT model are configured:

cpp if (!dev.setSensorClass(RbAmpSensorClass::Sct013)) { Serial.println(F("class set failed")); } if (!dev.setCTModel(3)) { // or your model: see below Serial.println(F("model set failed")); }

Without these two calls the calibration coefficients aren't loaded, and the current always reads as zero. This step is done once at first installation — the choice is saved to the module's flash.

  1. Check that the CT model matches the load. A large CT clamp (for example, SCT-013-100, 100 A) on a small load (a 50 W lamp = ~0.2 A) produces a signal right at the noise floor and the readings will be zero. Choose the smallest CT model that covers your maximum expected current. The full table is in 03 · Current sensor selection.

If you have a multi-channel module (UI2 / UI3) and you want to see both small loads and peak surges, consider the dual-CT pattern: a small clamp (for example, SCT-013-005) on a dedicated channel for the low range + a large one (SCT-013-030/100) on another channel for the high range; the master selects the value by a threshold. The pattern is discussed in 03 · Current sensor selection, section "Dual-CT topology".

  1. Check the clamp orientation. The arrow on the clamp body must point in the direction of current toward the load. If the clamp is "backwards", readCurrent() will give the correct magnitude, but readPower() will give a negative value on a consuming load. The confirmation — readPowerFactor() will show exactly −1.0 on a resistive load (instead of +1.0). The fix: either physically reinstall the clamp (unclip it, turn the arrow the right way, clip it back), or invert the sign on the master side.

If all three steps pass and the current is still zero

Then the signal at the ADC really is below the noise floor. Check:

  • Whether current is actually flowing — measure it with a multimeter (DC clamp / AC clamp meter) on the same wire.
  • Whether the clamp is intact — there should be an AC voltage at the clamp connector proportional to the current (a few millivolts for consumer loads).
  • Whether you're clamping the right wire — the line, not the neutral (although a clamp on the neutral will work too — it measures current amplitude, not direction).

Readings jump around or come back as NaN

What you observe: dev.readVoltage() or dev.readCurrent() periodically return NaN. dev.lastError() shows either RB_ERR_NACK or RB_ERR_NON_PHYSICAL.

If lastError() shows RB_ERR_NACK

See the "Module doesn't respond over I²C" section above — it's the same class of problem, with one difference: the link is partially working, but the retry budget occasionally runs out.

Steps:

  1. On ESP32 — lower the speed to 50 kHz + raise RBAMP_NACK_RETRY_ATTEMPTS=5.
  2. On other platforms — check the bus capacitance and the pull-ups.
  3. Monitor dev.retryExhaustionCount() to watch the trend.

If lastError() shows RB_ERR_NON_PHYSICAL

The library's sanity filter tripped: a float came off the bus that is either NaN, or Inf, or |x| > 10000 — obviously not a physical value. The library discards such a value and reports RB_ERR_NON_PHYSICAL instead of leaking garbage data into the application.

This is a rare artifact. The steady-state value of dev.sanityRejectCount() is 0. If it isn't zero:

  1. Check dev.retryExhaustionCount(). If both counters are nonzero, the link is unstable and the sanity filter is catching garbage after failed retries. Raise the retry budget (see above).
  2. If retryExhaustionCount == 0 but sanityRejectCount > 0, an artifact got through the retry layer. This happens under very heavy bus load. Raise RBAMP_NACK_RETRY_ATTEMPTS=5 and repeat the test.
cpp
Serial.print(F("retries exhausted: "));
Serial.print(dev.retryExhaustionCount());
Serial.print(F("  sanity rejects: "));
Serial.println(dev.sanityRejectCount());

Power Factor looks strange

What you observe: dev.readPowerFactor(0) returns a value that doesn't match the load type.

Expectations by load:

Load Expected PF
Kettle, iron, incandescent lamp +0.95 .. +1.0 (resistive)
Refrigerator, compressor motor +0.6 .. +0.85 (inductive)
LED lamp, TV (switching PSU) +0.5 .. +0.95 (nonlinear)
PV inverter exporting power negative PF

PF = NaN or 0 when I = 0

PF is defined as P / (U × I). At zero current I=0 the math is undefined. The specific value returned depends on the firmware (it may be NaN, 0, or a placeholder) — this is normal as long as the current is genuinely zero. Once there's current, there will be a valid PF.

PF is exactly −1.0 on a purely consuming load

The clamp is installed "backwards" — the arrow does not point in the direction of current toward the load. The fix: either reinstall the clamp correctly, or handle the sign on the master side (p = -p; pf = -pf; if you know the load can't be a PV inverter).

PF floats between +0.3 and +0.7 on a resistive load

  • Possible cause: the CT clamp is hanging on a wire of a different phase than the one the module's U input is connected to. In a distribution panel with several phases it's easy to clamp onto the wrong phase by mistake — a 120° or 180° phase shift between U and I gives exactly these PF values. The fix is to install the module so that the U input and the CT hang on the same phase.
  • Alternative: the load really isn't purely resistive. Repeat the test with a known resistive load (an electric kettle at full power).

Period snapshots are always stale

What you observe: dev.readPeriodSnapshot(snap) returns false with lastError() == RB_ERR_STALE. This means the module didn't finish integrating the previous period by the time of the next read.

The library protects against double-counting Wh: on a stale read it records a master timestamp, and the next successful snapshot covers one period, not two.

Acceptable: rare stales (1–2 per hour at a 60 s cadence). Not acceptable: consecutive stales — that means the firmware is unresponsive or the master is polling too often.

Cadence check procedure

  1. Check the cadence: 60 s between latches is comfortable; 30 s is marginal; < 10 s guarantees stales.
  2. Check the module's responsiveness between snapshots:

cpp if (dev.probe()) { Serial.println(F("alive")); }

  1. Direct flag checkdev.isPeriodValid() does a single-byte read with no side effects.
  2. Check the firmware versiondev.firmwareVersion() should report 0x04 (v1.3, current production); older firmware (0x01 v1.0 / 0x02 v1.1 / 0x03 v1.2) shows more stales.

Wh accounting diverges from a reference

What you observe: dev.energy().wh(0) diverges, after several hours / days of operation, from the reading of the utility meter or a reference meter (Kill-A-Watt and the like).

First rule out the trivial

  1. Current sensor calibration: make sure setSensorClass() and setCTModel() were called with the correct CT model (see 03 · Current sensor selection). Without this, the RMS current is computed with the default floor and the power value will be systematically biased.
  2. Dropped stale snapshots: if dev.energy().wh() is consistently lower than the reference, this could be missed intervals — a snapshot came back stale, the library protected against double-counting, but the interval measurement was lost. Check the cadence (see above).
  3. Master clock drift: millis() by itself is reliable. But if the master enters deep-sleep without preserving the RTC, the interval between the previous and the next latch is lost. Enable the RTC for such scenarios.

Accumulator accuracy by platform

Platform Accumulator type Long-term accuracy
ESP32 / ESP8266 / STM32duino / SAMD / RP2040 64-bit double drift < 1 LSB / year @ 60 s cadence
Arduino AVR (Uno, Mega, Nano) 32-bit float (toolchain) ~0.01 % drift per day

For AVR on long soak installations, periodically reset the accumulator and save the long-term total to your own persistent store:

cpp
// Once a day in the MQTT-publish hook
mqtt.publish("rbamp/wh_daily", String(dev.energy().wh(0)));
dev.energy().reset(0);

snap.latch_ms reads ~27% short of the real period — this is EXPECTED, not a bug

What you observe: if, for your own diagnostics, you divide snap.latch_ms (the chip-side software timer) by the real wall-clock time between two readPeriodSnapshot() calls, the ratio comes out at ~0.73 (that is, the chip-side timer undercounts by ~27%).

This is by design and HW-validated (bench measurements across all 4 sister-libs: esp-idf 0.7396, arduino 0.729, python 0.743 — all converge in the 26-27% window). The cause is SysTick starvation on the slave: under load, DMA/ISR leave too little cycle budget for regular incrementing of the software timer. latch_ms (register 0xEC) is intended only as a diagnostic indicator of slave activity, NOT for billing.

Canon: dev.energy().wh(ch) integrates over the master millis() (the master's wall-clock), not over snap.latch_ms. The Arduino library's Wh accounting is accurate — bench measure: relative error vs independent ground-truth = 0.0000% (lib integration math avg_p × master_dt / 3600000 exact). All 4 sister-libs (arduino, esp-idf, python, esphome) use the same canon.

If your code relies on snap.latch_ms for some sub-period computations, switch to your own millis(). If you just see the discrepancy in the logs and are worried — it's normal; remove the discrepancy from your diagnostics or accept the 27% gap as expected.

RB_ERR_STALE on every read — the master automatically holds the anchor

What you observe: dev.readPeriodSnapshot(snap) periodically returns false with lastError() == RB_ERR_STALE. (See also the "Period snapshots are always stale" section above.)

Canonical dt-handling: on a stale read the Arduino library does NOT zero its internal _last_latch_ms anchor. The next valid read gets a master_dt equal to the full interval since the previous successful snapshot — that is, it covers both the "lost" stale period and the current one. The firmware preserves the avg_p accumulator across an empty latch (firmware-side persistence): on the next valid latch this is already the value averaged over the whole interval. The Wh integration stays accurate — no double-count, no under-count.

No special stale handling is needed in the master's code: the library does everything correctly, automatically. Just ignore RB_ERR_STALE if it's rare; if it's frequent, diagnose the cadence (section above).


ESP32 sketch hangs after a few minutes

What you observe: the sketch on ESP32 starts up fine, then goes into a hang / restart loop / WDT timeout after 1–30 minutes.

Wire hangs on a marginal bus — three-layer mitigation

What you observe specifically: a sketch on ESP32 (Arduino-ESP32 core) polls rbAmp fine for several minutes, then "dead" hangs in the middle of a dev.readAll(...) / dev.readVoltage() / fleet.pollAll() call. If task-WDT is enabled, it catches the hang; otherwise the sketch just stops responding. The decoded backtrace ends at the function i2c_ll_is_bus_busy (the IDF i2c_master driver, file i2c_master.c:526, pre-send bus-busy wait).

What's happening: the Arduino-ESP32 Wire wraps the same IDF i2c_master driver as native ESP-IDF projects. On a marginal bus (weak pull-ups, long traces, EMI, ZC interference), SDA/SCL can briefly "stick" in an undefined state. Before each transaction the IDF i2c_master spins in the i2c_ll_is_bus_busy loop, waiting for the bus to free up — this spin is NOT bounded by the library's I²C timeout. If bus-busy holds longer than the spin lasts without servicing other tasks, the FreeRTOS IDLE task doesn't get the CPU, and the whole sketch hangs.

This is not a "debugger-only artifact". Validated on the bench (the same hardware harness and load):

Bus configuration Hang rate
2 weak module pull-ups + debugger NRST attached ~1 hang / 2.1 min
1 weak module pull-up, no debugger ~1 hang / 3.3 min (≈ 12 hangs per hour)
+ external 4.7 kΩ pull-up on the DUT SDA/SCL 0 hangs (12-min soak, 1300 cycles, 0 reboots, 0 WDT triggers)

The correlation is clear — the bus-integrity fix removes the hang entirely. The library logic is not implicated: RbAmpFleet::pollAll(), MISS-individual modules, and the retry/sanity counters stayed clean on every run right up to the hang itself.

Three-layer mitigation (apply all three layers):

  1. External pull-up (~4.7 kΩ) on SDA and SCL to 3.3 V at a single point on the bus. The ESP32-internal pull-ups (~45 kΩ) and the ones built into the modules (~10 kΩ with N modules in parallel) are weak for a multi-module bus of real length. Cut the built-in ones on all modules but one (or on all of them — then you rely solely on the external ones). See 04 · Wiring section "Multi-module bus — the primary topology".
  2. Don't run a production build with the debugger NRST attached. In a debug session the reset line can hold SDA/SCL in an undefined state on detach/attach, triggering a bus-wedge on the next transaction. On a field build (no debugger) this factor goes away.
  3. App-level task-WDT on the poll task — defense-in-depth. If for some reason the pull-ups stayed marginal, or some other cause of a wedge arose, the WDT will reboot the sketch. Bench 12-min soak: the WDT caught and recovered all 12 hangs in the configuration without an external pull-up. Proper bus pull-ups — field fix; app-WDT — recovery posture.
cpp
#include "esp_task_wdt.h"
void setup() {
    // Layer 3 setup — defense-in-depth.
    esp_task_wdt_config_t wdt_cfg = {
        .timeout_ms = 8000,            // 8 s with a large margin
        .idle_core_mask = 0,
        .trigger_panic = true,         // on timeout — panic+reboot
    };
    esp_task_wdt_reconfigure(&wdt_cfg);
    esp_task_wdt_add(NULL);            // this task (loop) under WDT
    // ... rest of the initialization ...
}
void loop() {
    fleet.pollAll(snaps, status, RBAMP_FLEET_MAX_MODULES, n_ok);
    // ... processing ...
    esp_task_wdt_reset();              // "I'm alive" — every cycle
    delay(200);
}

What NOT to do: don't try to work around the problem with a larger Wire.setTimeout() parameter — it doesn't bound the bus-busy pre-spin, which is a different code path in the IDF driver. The fix is bus integrity (layer 1) + a supervisor (layer 3).

Watchdog timeout in wifi_connect()

Cause: the unbounded loop while (WiFi.status() != WL_CONNECTED) delay(500) triggers the task-WDT after ~5 s (default).

Fix: a bounded wait with a restart fallback:

cpp
uint32_t t0 = millis();
while (WiFi.status() != WL_CONNECTED) {
    delay(500);
    if (millis() - t0 > 30000) { ESP.restart(); }
}

The MQTT broker disconnects every ~15 s

Cause: PubSubClient defaults to keepalive = 15 s, while mqtt.loop() is called only in the "slow" path (once every 60 s together with readPeriodSnapshot()).

Fix: set the keepalive to 60 s and call mqtt.loop() on every pass of loop():

cpp
mqtt.setKeepAlive(60);
void loop() {
    if (!mqtt.connected()) mqtt.connect("rbamp-id");
    mqtt.loop();    // every iteration, not once every 60 s
    // ...rest of the logic, slowed down via millis()...
}

TLS handshake fail (cloud integrations)

Cause: the ESP32 heap is insufficient for the TLS handshake (~30 kB required). It often combines with WiFi + MQTT + buffers — leaving < 20 kB.

Fix:

  • Trim setBufferSize() for the MQTT client to the minimum.
  • Use WiFi.mode(WIFI_STA) (not WIFI_AP_STA).
  • Disable BLE: btStop() in setup().

If ESP.getFreeHeap() shows < 25 kB before client.connect(), the TLS handshake will most likely fail.


setSensorClass() / setCTModel() returns RB_ERR_PARAM

What you observe: one of the configuration calls returns false, lastError() == RB_ERR_PARAM.

Possible causes:

  1. setCTModel() called before setSensorClass(). Sensor class first, then model — see 03 · Current sensor selection and 09 · API reference § Sensor configuration.
  2. Invalid model code — for the Sct013 class the valid set is {1, 2, 3, 4, 6} (non-contiguous; code 5 is reserved in v1.3 firmware, the former SCT-013-100). For other classes, see the per-class accept-set table in 03 · Current sensor selection. Codes that don't match the class return RB_ERR_PARAM (lib-side pre-bus guard) or DEV_ERR_PARAM (firmware-side, if YAML slips past).
  3. Invalid channel index in the per-channel form setCTModel(channel, code) — it must be < dev.channels().

Error handling: REG_ERROR last-write + EVENT_FLAGS.bit3 durable (v1.3)

v1.3 canon (HW-confirmed): REG_ERROR (0x02) is last-write-outcome, and NOT sticky. On each register write the firmware sets reg_error = ERR_OK; a subsequent unrelated write clears the previous error.

Durable error signal = EVENT_FLAGS (0x2A) bit3 — sticky (W1C), asserted immediately on any rejected write/command.

Pattern 1 — one-off post-operation capture (if the outcome of this specific operation matters):

cpp
bool ok = dev.saveUserConfig();
uint8_t dev_err = dev.readReg(0x02);   // IMMEDIATELY, before the next write

Pattern 2 — durable error monitoring (canonical):

cpp
uint8_t event_flags = dev.readReg(0x2A);
if (event_flags & (1 << 3)) {
    uint8_t last_err = dev.readReg(0x02);
    // handle
    dev.writeReg(0x2A, (1 << 3));        // W1C clear bit3
    // or dev.clearError();
}

REVERSAL of the previous "sticky" documentation (v1.3 A3 root canon). REG_ERROR is last-write-outcome, not sticky. Durability is provided by EVENT bit3.

bit3 is an async channel, not for synchronous write validation: on a rejected write, bit3 is set with a delay relative to the moment the I²C transaction returns. Don't poll bit3 immediately after a write to check that write's outcome — for the outcome of your own write use Pattern 1 (one-off lastError() capture right after the operation) or the setter's return code. bit3 is for long-running monitoring of async facts (runtime, command-path), not for validating an operation you just performed.

lastError() vs readLastError() — two different channels, not synonyms

Two functions with similar names, but completely different semantics:

lastError() readLastError(out)
What it returns Library-cached RB_ERR_* code from the previous lib call A single wire-read of the device's REG_ERROR (0x02) register
An I²C operation? No — just a memory read Yes — a single read transaction
Semantics Lib-side validation outcome (client guard, retry-state, etc.) Device-side last-write outcome (DEV_ERR_* mnemonic)
When updated After every lib method After every bus-accepted write on the device
Example value RB_ERR_PARAM after a client-side guard 0xFE (DEV_ERR_PARAM) after a rejected write on the device
Example of mismatch lastError() == RB_ERR_PARAM (the setter blocked it pre-bus) readLastError() → 0x00 (nothing reached the device)

When to use each: - lastError() — for application logic, parsing lib-side outcomes (retry, fallback, error classification), with no I²C overhead. - readLastError() — when you want the extended device-side cause code (for example, DEV_ERR_PARAM (0xFE) vs DEV_ERR_NOT_READY vs DEV_ERR_FLASH_PARAMS_BAD (0xFB)) on Channel B (DUT-side rejection). See the §"v1.3 error model — two independent channels" in 09 · API reference.

The distinction is especially important when debugging Channel A (client-side guard): the setter returns false + lastError() == RB_ERR_PARAM, but readLastError() == 0x00 — because the lib blocked it before the wire operation, and REG_ERROR on the device was not touched.

Caveat: DEV_ERR_CLONE (0xF9) is NOT cleared via CMD_CLEAR_ERROR — it's an anti-clone sentinel (only a reboot or a factory reset).


A fresh-flash module shows 0xFB on the first boot (NORMAL)

What you observe: a freshly flashed module on its first boot shows REG_ERROR = 0xFB (DEV_ERR_FLASH_PARAMS_BAD) + EVENT bit3.

Cause: the params page is uninitialized → factory defaults loaded. This is NORMAL for a virgin module, not fatal.

Fix: configure sensor_class + ct_model + (optionally) address, then dev.saveUserConfig(). After a successful SAVE → REG_ERROR = 0x00, bit3 clear.


commitAddressChange() returns RB_ERR_TIMEOUT

What you observe: prepareAddressChange() went through, but commitAddressChange() returns false, lastError() == RB_ERR_TIMEOUT.

Cause: the armed-state window (5 s after prepareAddressChange) expired. WiFi/MQTT/any blocking I/O between prepare and commit is the main source of the window expiring. dev.probe() won't help here (the module responds; the problem is in the state machine).

What to do: call prepareAddressChange() again and immediately, in the same loop() iteration, with no network calls in between, call commitAddressChange().

REG_I2C_ADDRESS (0x30) now reads the ACTIVE address at boot (v1.3 Fix 4 addr-boot-sync). After a post-commit reboot, reading 0x30 will show the new active address. For the most reliable verification of a two-phase address commit, try a read at the new address (it should ACK on the bus). After a host-write (staging), the register echoes the staged candidate until CMD_COMMIT_ADDR + reset — this is by-design behaviour.

For more on the two-phase address commit, see 09 · API reference and 04 · Wiring.


Reads fail while switching relay loads (EMI transients)

What you observe: dev.readVoltage() / dev.readCurrent() periodically return NAN, lastError() == RB_ERR_NACK or RB_ERR_IO — but only during active switching of a relay/inductive load on the same setup. Steady-state reads are reliable.

Cause (C.12 HW-confirmed root 2026-06-15): during relay switching (a 5 A load) EMI fails ~67% of I²C transactions (~8/12 in the hw measurement). The bus self-recovers, no wedge occurs, no module is lost — but the current read fails.

Fix — application-level retry:

cpp
float robust_read_voltage(RbAmp& dev) {
    for (int attempt = 0; attempt < 5; attempt++) {
        float v = dev.readVoltage();
        if (!isnan(v)) return v;
        delay(20);   // a short pause before the retry
    }
    return NAN;
}

Library-side bus recovery is not sufficient on its own: when an EMI glitch overlaps the driver's retry window, an explicit application-level retry with a pause is needed.

Alternative: if the master sees the relay-switching events, delay reads by ~50-100 ms after the commutation.


Error code summary table

dev.lastError() returns one of these codes after every public API call. RbAmp::errorString(code) returns a human-readable string.

Code String When Where to look
RB_OK (0) "OK" success
RB_ERR_IO (-1) "I2C transport failure" the bus driver returned non-OK wiring, power, pull-ups
RB_ERR_NACK (-2) "NACK — device absent or busy" retry exhausted "Module doesn't respond over I²C" section
RB_ERR_TIMEOUT (-3) "Bus timeout" the waitReady / commitAddressChange window expired "commitAddressChange() returns RB_ERR_TIMEOUT" section
RB_ERR_NOT_READY (-4) "Device not ready" (reserved)
RB_ERR_STALE (-5) "Period snapshot stale" the period-ready flag = 0 "Period snapshots are always stale" section
RB_ERR_PARAM (-6) "Bad parameter" invalid channel index / invalid model code / invalid address range "setSensorClass() / setCTModel() returns RB_ERR_PARAM" section
RB_ERR_MODE (-7) "Operation requires develop mode" a factory-only operation (for example saveGains() in production) do not call factory-only operations on production firmware — these are blocked by design
RB_ERR_CHECKSUM (-8) "Codegen parity mismatch" (reserved for codegen CI)
RB_ERR_VERSION (-9) "Unsupported firmware version" REG_VERSION = 0 / 0xFF check the module connection
RB_ERR_NOT_IMPLEMENTED (-10) "Not implemented" (reserved)
RB_ERR_NON_PHYSICAL (-11) "Non-physical value (NaN/Inf/out-of-bounds)" the sanity filter rejected a float "Readings jump around or come back as NaN" section

Diagnostic counter summary table

In a healthy soak run (12 h, the SoakMonitor sketch) all stay zero:

Counter Steady-state Reset
dev.retryExhaustionCount() 0 dev.resetCounters()
dev.sanityRejectCount() 0 dev.resetCounters()
dev.lastError() after a read RB_OK (0) automatically on the next call
stale fraction in period snapshots < 1 % (cumulative — no reset)

If any of these are nonzero in steady state, go back to the corresponding section above.


Bus-level debug with a logic analyzer

For deep debugging, when the library can no longer tell you what's happening on the wire, capture SDA + SCL with a logic analyzer (Saleae, DSLogic Plus, a Sigrok-compatible one):

  • Sample rate ≥ 1 MS/s at 100 kHz I²C; ≥ 4 MS/s at 400 kHz.
  • The I²C decoder in Sigrok / Saleae will show ACK / NACK on each byte
  • the address phase.
  • Compare your sketch's calls (dev.readVoltage() etc.) against the expected byte sequence — they should match exactly. Burst-reads (several bytes in one transaction via address auto-increment) are supported. Writes are NOT auto-increment — each byte is a separate transaction.

If the library's behaviour diverges from the capture, open an issue with the capture file attached (.sal / .dsl / .csv).


When to contact support

If you've worked through the relevant section above and the problem persists, open an issue:

github.com/rb-amp/rbamp-arduino/issues

In the issue, include:

  • Host MCU + Arduino core version (for example, ESP32-S3 on Arduino-ESP32 3.0.4).
  • Library version (RbAmp from the Library Manager).
  • Module firmware versiondev.firmwareVersion().
  • Minimal sketch that reproduces the problem (~30 LOC).
  • dev.lastError() + dev.errorString(dev.lastError()) + dev.retryExhaustionCount() + dev.sanityRejectCount() at the moment of failure.
  • (If available) a logic-analyzer capture file from the moment of failure.