This chapter answers two questions:

  1. Which current sensor to choose for a given load.
  2. How to tell the rbAmp module about your choice, so that the factory calibration for that combination loads automatically.

The physical sensor connection (clamp orientation, L/N polarity check) is covered in 04_hardware.md. This chapter is about model selection and the API calls.


Sensor class

rbAmp modules work with CT clamps of the SCT-013 family. The sensor class is determined by the module's hardware revision and is set at the factory — the user reports their choice via dev.set_sensor_class() before selecting a specific CT-clamp model.


Choosing the SCT-013 model

The SCT-013 family has five models, differing in the maximum primary-circuit current:

code Model Current range Typical use
1 SCT-013-005 0…5 A Small loads — lamps, low-power electronics, a single switch
2 SCT-013-010 0…10 A One medium-power appliance — refrigerator, washing machine, AC unit up to 2 kW
3 SCT-013-030 0…30 A A mid-size household service entrance — up to ~7 kW
4 SCT-013-050 0…50 A A large service entrance — electric heating, EV charger, a house with peak loads
5 SCT-013-100 0…100 A A house or small-office mains feed — up to ~23 kW

How to pick the right model

The basic rule:

  1. Determine the maximum current that can flow in the circuit (the largest load + 30% headroom).
  2. Choose the model whose range that value fits into.
  3. Don't over-size by more than 5×. An SCT-013-100 clamp on a circuit with a 5 A maximum will work, but it gives low resolution and high error at typical values.

Headroom

An SCT-013 clamp operates without saturation within its rated range. Brief peaks (compressor inrush, an inductive load) may exceed the rating by 5–7× — this is normal; the clamp physically withstands it, but the measurement becomes nonlinear above the rating.

If your load has a peak current above the clamp's rating, choose the next size up. For example, for a washing machine with a 12 A inrush current (but a 2–3 A rating while running), SCT-013-030 is better than SCT-013-005.


How to tell the module about your choice

Two calls are required, in the correct order — first dev.set_sensor_class(), then dev.set_ct_model(). If you call dev.set_ct_model() before dev.set_sensor_class() on v1.2+ firmware, the package raises RbAmpModeError:

text
REG_SENSOR_CLASS is UNSET on v1.2+ firmware;
call dev.set_sensor_class(RbAmpSensorClass.SCT_013) first
python
from rbamp import RbAmp, RbAmpSensorClass, RbAmpModeError
with RbAmp(bus, 0x50) as dev:
    # Step 1: the sensor class. REQUIRED before set_ct_model().
    try:
        dev.set_sensor_class(RbAmpSensorClass.SCT_013)
    except RbAmpModeError as e:
        # Possible causes: communication failure (see 10 · Troubleshooting),
        # invalid argument (cls outside the known values)
        print("set_sensor_class failed:", e)
        return
    # Step 2: the model within the family.
    # 1 = SCT-013-005, 2 = SCT-013-010, 3 = SCT-013-030,
    # 4 = SCT-013-050, 5 = SCT-013-100.
    try:
        dev.set_ct_model(3)   # e.g., SCT-013-030
    except RbAmpModeError:
        print("Sensor class must be set first (v1.2+ firmware guard)")
    except ValueError:
        print("Code out of range (must be 1..5)")

set_sensor_class() accepts either an enum or a plain int — both forms are equivalent:

python
dev.set_sensor_class(RbAmpSensorClass.SCT_013)  # explicit enum form
dev.set_sensor_class(1)                          # numeric (equivalent)

The package deliberately does NOT call set_sensor_class() for you. If this step is skipped on v1.2+ firmware, set_ct_model() raises RbAmpModeError without writing to flash. This is done so the behavior is predictable and explicit — no "magic" in the public API.

On v1.0 / v1.1 firmware the guard is skipped (backward compat — set_ct_model() writes to REG_CT_MODEL directly, as before).

After these two calls:

  • The module stores both values in flash — the setting survives a reset, a power cycle, and a firmware re-flash.
  • The calibration coefficients for that specific combination (sensor class + model) load from the factory preset table. You don't need to touch any manual calibration registers.
  • The next read of dev.current[0] (or dev.read_current(0)) already returns a value in amperes with the correct scaling.

Total time for both calls is about 1.4 seconds (two flash-write operations × ~700 ms each, limited by the flash page erase time). It is done once at first installation; the setting persists in flash and is not repeated.

If you already selected a sensor on first run and are simply restarting the script, there's no need to repeat the set_sensor_class() and set_ct_model() calls — the module remembers the previous choice. But it does no harm either — calling again with the same value just rewrites the same byte.

Verifying the setup

A simple sanity check after set_ct_model():

python
import time
from rbamp import RbAmp, RbAmpSensorClass
def sanity_check(dev):
    print("Ready. Connect a purely resistive load",
          "(e.g., an incandescent lamp).")
    print("Expect a stable PF ~= 1.0 and positive P.")
    while True:
        u  = dev.voltage              # property — one I²C transaction
        i  = dev.read_current(0)
        p  = dev.read_power(0)
        pf = dev.read_power_factor(0)
        print(f"U={u:.1f} V  I={i:.2f} A  P={p:.1f} W  PF={pf:.2f}")
        time.sleep(2)
with RbAmp(bus, 0x50) as dev:
    dev.set_sensor_class(RbAmpSensorClass.SCT_013)
    dev.set_ct_model(3)
    sanity_check(dev)

On MicroPython, replace time.sleep(2) with time.sleep_ms(2000).

On a purely resistive load (incandescent lamp, electric kettle, heating element), expect:

  • U ≈ 220–240 V (for 230 V grids)
  • I ≈ corresponds to the load's power (P / U)
  • P > 0 and stable
  • PF ≈ 1.0 (strictly positive)

If something doesn't add up, see 10_troubleshooting.md.


Modules with multiple current channels

On the UI2, UI3, I2, I3 modules, each current channel has an independent SCT-013 model selection. You can connect, for example, SCT-013-005 on channel 0 (a single outlet), SCT-013-030 on channel 1 (a stove line), and SCT-013-100 on channel 2 (the mains feed).

The API for per-channel selection is dev.set_ct_model_ch(channel, code) (added in v1.1.0):

python
dev.set_sensor_class(RbAmpSensorClass.SCT_013)   # once for all channels
# IMPORTANT: assign channels from highest to lowest (descending order).
# First channel 2, then 1, then 0. See below for why.
dev.set_ct_model_ch(2, 5)   # channel 2: SCT-013-100
dev.set_ct_model_ch(1, 3)   # channel 1: SCT-013-030
dev.set_ct_model_ch(0, 1)   # channel 0: SCT-013-005

Order matters. Each dev.set_ct_model_ch(channel, code) call also applies the same code to channel 0 as a side effect — this is the legacy compatibility path with v1.1 firmware (the single-arg set_ct_model(code) always wrote to channel 0 directly). If you assign channels in forward order (0,1) → (1,3) → (2,5), the last call overwrites ch0 with the value 5, and the final state is ch0=5, ch1=3, ch2=5 — incorrect.

The correct order is from the highest channel to the lowest: the last call, with channel=0, pins the final ch0 value.

If all channels get the same model, order doesn't matter (the side effect is idempotent):

python
dev.set_sensor_class(RbAmpSensorClass.SCT_013)
dev.set_ct_model_ch(0, 1)
dev.set_ct_model_ch(1, 1)   # ch0 is overwritten with the same value
dev.set_ct_model_ch(2, 1)

The single-parameter dev.set_ct_model(code) remains for backward compat with UI1 modules (it applies to channel 0). On multi-channel modules it is equivalent to dev.set_ct_model_ch(0, code).

On v1.0/v1.1 firmware (REG_VERSION < 0x03) the per-channel opcodes CMD_SET_CT_MODEL_CHn do not exist — dev.set_ct_model_ch(channel, code) raises RbAmpVersionError without writing. Use the single-parameter dev.set_ct_model(code), which writes to channel 0 via the legacy path.


Advanced setup: two clamps of different ratings on one wire

An advanced pattern, not a basic one. This section describes an optional technique for improving resolution at low currents. For most installations, a single clamp matched to the load range is sufficient. Use dual-CT only if you have a specific accuracy requirement at currents < 1 A.

When it applies

  • Multi-channel UI2 / UI3 modules on v1.2+ firmware.
  • The same wire needs to be measured both for small loads (≤ 1 A) and for peak events (≥ 5 A) with equal quality.
  • A typical example: an apartment service entrance with 50–100 W standby during the day, and a kettle or electric stove drawing 3+ kW in the evening.

The idea

Two SCT-013 clamps of different ratings are installed on the same wire:

  • Channel 0 — the small clamp (e.g., SCT-013-005, 5 A): sees small currents with better resolution and a lower noise floor.
  • Channel 1 — the large clamp (e.g., SCT-013-030 or higher): handles currents above the small clamp's overload point without saturation.

The master decides which channel to use based on the current value — while the small clamp is in its linear range, its reading is more accurate; above that, it switches to the large one.

Configuration (descending order — mandatory)

The sensor class first, once, then the models in order from the highest channel to the lowest — otherwise the legacy REG_CT_MODEL side effect overwrites channel 0 with the value of the last call (see the warning in the previous section, "Modules with multiple current channels").

python
dev.set_sensor_class(RbAmpSensorClass.SCT_013)   # once
# First channel 1 (the large clamp), then channel 0 (the small one) —
# so the final ch0 value is correct.
dev.set_ct_model_ch(1, 3)   # ch1 = SCT-013-030 (0..30 A)
dev.set_ct_model_ch(0, 1)   # ch0 = SCT-013-005 (0..5 A)

Final state: ch0 = SCT-013-005, ch1 = SCT-013-030. ✓

Aggregation logic on the master side

The simplest pattern is to switch on a threshold:

python
import math
def read_combined_current(dev):
    """Read the combined current — picks low-CT when in its linear range,
    otherwise falls back to the high-CT.
    """
    i_low  = dev.read_current(0)   # the small clamp
    i_high = dev.read_current(1)   # the large clamp
    # While the small clamp is far from saturation, it gives better
    # accuracy at low currents. Switch to the large one as it
    # approaches its overload point.
    #
    # The 4.5 A threshold for SCT-013-005 is PROVISIONAL; the exact
    # value will be determined by bench validation (see below, re IP-010).
    # Behavior near the threshold is a matter of measurement, not estimate.
    if not math.isnan(i_low) and i_low < 4.5:
        return i_low
    return i_high

📷 An installation diagram is expected. Two clamps on one wire are physically possible on most household-gauge cables, but they need a little room in the panel. A detailed diagram — including the arrow orientation of both clamps and the allowable distances between them — will appear here as it is prepared.

Bench validation. The exact figures for the dual-CT pattern (behavior near the threshold, temperature drift, the divergence of the two clamps in the overlapping range) are established by the IP-010 measurement program (the successor to IP-001). Until it is complete, treat dual-CT as a pilot pattern; for critical applications, a single clamp matched to the upper end of the load range is preferable.

Approaches to improving low-current sensitivity

If your load has a wide dynamic range (for example, 1 W router standby vs. a 2000 W water heater on the same outlet), a single clamp sized for the upper limit loses the lower currents in the noise.

Three strategies, in increasing order of complexity:

  1. Size the CT to the maximum, not "with margin". The most common mistake is putting an SCT-013-100 (100 A) on a household outlet with typical consumption of 0.5–10 A. The signal sits in the bottom 1–10% of the ADC — where noise becomes comparable to the signal. For a household scenario (a 16 A outlet) SCT-013-030 is optimal; for connecting a single device (≤ 5 A), SCT-013-005.
  2. Dual-CT topology (requires a UI2/UI3 SKU): a small clamp for the low range + a large one for the high range, with the master choosing by threshold. See the "Dual-CT topology" section above — the pattern is a pilot, and the numbers are being refined by the IP-010 program.
  3. Bench calibration of the noise floor (factory-side): IP-001 characterizes the noise floor on a test bench; the results are baked into the firmware's calibration array. On the user side, nothing needs to be done beyond set_sensor_class() + set_ct_model(). Until the program is complete, the specific low-current accuracy numbers are not published.

What's next