Sensor Selection
This chapter answers two questions:
- Which current sensor to choose for a given load.
- How to tell the rbAmp module about your choice, so that the factory calibration for that combination loads automatically.
The physical sensor connection (clamp orientation, L/N polarity check) is covered in 04_hardware.md. This chapter is about model selection and the API calls.
Sensor class
rbAmp modules work with CT clamps of the SCT-013 family. The
sensor class is determined by the module's hardware revision and is
set at the factory — the user reports their choice via
dev.set_sensor_class() before selecting a specific CT-clamp
model.
Choosing the SCT-013 model
The SCT-013 family has five models, differing in the maximum primary-circuit current:
code |
Model | Current range | Typical use |
|---|---|---|---|
| 1 | SCT-013-005 | 0…5 A | Small loads — lamps, low-power electronics, a single switch |
| 2 | SCT-013-010 | 0…10 A | One medium-power appliance — refrigerator, washing machine, AC unit up to 2 kW |
| 3 | SCT-013-030 | 0…30 A | A mid-size household service entrance — up to ~7 kW |
| 4 | SCT-013-050 | 0…50 A | A large service entrance — electric heating, EV charger, a house with peak loads |
| 5 | SCT-013-100 | 0…100 A | A house or small-office mains feed — up to ~23 kW |
How to pick the right model
The basic rule:
- Determine the maximum current that can flow in the circuit (the largest load + 30% headroom).
- Choose the model whose range that value fits into.
- Don't over-size by more than 5×. An SCT-013-100 clamp on a circuit with a 5 A maximum will work, but it gives low resolution and high error at typical values.
Headroom
An SCT-013 clamp operates without saturation within its rated range. Brief peaks (compressor inrush, an inductive load) may exceed the rating by 5–7× — this is normal; the clamp physically withstands it, but the measurement becomes nonlinear above the rating.
If your load has a peak current above the clamp's rating, choose the next size up. For example, for a washing machine with a 12 A inrush current (but a 2–3 A rating while running), SCT-013-030 is better than SCT-013-005.
How to tell the module about your choice
Two calls are required, in the correct order — first
dev.set_sensor_class(), then dev.set_ct_model(). If you call
dev.set_ct_model() before dev.set_sensor_class() on v1.2+
firmware, the package raises RbAmpModeError:
REG_SENSOR_CLASS is UNSET on v1.2+ firmware;
call dev.set_sensor_class(RbAmpSensorClass.SCT_013) firstfrom rbamp import RbAmp, RbAmpSensorClass, RbAmpModeError
with RbAmp(bus, 0x50) as dev:
# Step 1: the sensor class. REQUIRED before set_ct_model().
try:
dev.set_sensor_class(RbAmpSensorClass.SCT_013)
except RbAmpModeError as e:
# Possible causes: communication failure (see 10 · Troubleshooting),
# invalid argument (cls outside the known values)
print("set_sensor_class failed:", e)
return
# Step 2: the model within the family.
# 1 = SCT-013-005, 2 = SCT-013-010, 3 = SCT-013-030,
# 4 = SCT-013-050, 5 = SCT-013-100.
try:
dev.set_ct_model(3) # e.g., SCT-013-030
except RbAmpModeError:
print("Sensor class must be set first (v1.2+ firmware guard)")
except ValueError:
print("Code out of range (must be 1..5)")set_sensor_class() accepts either an enum or a plain int —
both forms are equivalent:
dev.set_sensor_class(RbAmpSensorClass.SCT_013) # explicit enum form
dev.set_sensor_class(1) # numeric (equivalent)The package deliberately does NOT call
set_sensor_class()for you. If this step is skipped on v1.2+ firmware,set_ct_model()raisesRbAmpModeErrorwithout writing to flash. This is done so the behavior is predictable and explicit — no "magic" in the public API.On v1.0 / v1.1 firmware the guard is skipped (backward compat —
set_ct_model()writes toREG_CT_MODELdirectly, as before).
After these two calls:
- The module stores both values in flash — the setting survives a reset, a power cycle, and a firmware re-flash.
- The calibration coefficients for that specific combination (sensor class + model) load from the factory preset table. You don't need to touch any manual calibration registers.
- The next read of
dev.current[0](ordev.read_current(0)) already returns a value in amperes with the correct scaling.
Total time for both calls is about 1.4 seconds (two flash-write operations × ~700 ms each, limited by the flash page erase time). It is done once at first installation; the setting persists in flash and is not repeated.
If you already selected a sensor on first run and are simply restarting the script, there's no need to repeat the
set_sensor_class()andset_ct_model()calls — the module remembers the previous choice. But it does no harm either — calling again with the same value just rewrites the same byte.
Verifying the setup
A simple sanity check after set_ct_model():
import time
from rbamp import RbAmp, RbAmpSensorClass
def sanity_check(dev):
print("Ready. Connect a purely resistive load",
"(e.g., an incandescent lamp).")
print("Expect a stable PF ~= 1.0 and positive P.")
while True:
u = dev.voltage # property — one I²C transaction
i = dev.read_current(0)
p = dev.read_power(0)
pf = dev.read_power_factor(0)
print(f"U={u:.1f} V I={i:.2f} A P={p:.1f} W PF={pf:.2f}")
time.sleep(2)
with RbAmp(bus, 0x50) as dev:
dev.set_sensor_class(RbAmpSensorClass.SCT_013)
dev.set_ct_model(3)
sanity_check(dev)On MicroPython, replace time.sleep(2) with time.sleep_ms(2000).
On a purely resistive load (incandescent lamp, electric kettle, heating element), expect:
U≈ 220–240 V (for 230 V grids)I≈ corresponds to the load's power (P / U)P> 0 and stablePF≈ 1.0 (strictly positive)
If something doesn't add up, see 10_troubleshooting.md.
Modules with multiple current channels
On the UI2, UI3, I2, I3 modules, each current channel has
an independent SCT-013 model selection. You can connect, for
example, SCT-013-005 on channel 0 (a single outlet), SCT-013-030
on channel 1 (a stove line), and SCT-013-100 on channel 2 (the
mains feed).
The API for per-channel selection is
dev.set_ct_model_ch(channel, code) (added in v1.1.0):
dev.set_sensor_class(RbAmpSensorClass.SCT_013) # once for all channels
# IMPORTANT: assign channels from highest to lowest (descending order).
# First channel 2, then 1, then 0. See below for why.
dev.set_ct_model_ch(2, 5) # channel 2: SCT-013-100
dev.set_ct_model_ch(1, 3) # channel 1: SCT-013-030
dev.set_ct_model_ch(0, 1) # channel 0: SCT-013-005⚠ Order matters. Each
dev.set_ct_model_ch(channel, code)call also applies the samecodeto channel 0 as a side effect — this is the legacy compatibility path with v1.1 firmware (the single-argset_ct_model(code)always wrote to channel 0 directly). If you assign channels in forward order(0,1) → (1,3) → (2,5), the last call overwrites ch0 with the value 5, and the final state isch0=5, ch1=3, ch2=5— incorrect.The correct order is from the highest channel to the lowest: the last call, with
channel=0, pins the final ch0 value.
If all channels get the same model, order doesn't matter (the side effect is idempotent):
dev.set_sensor_class(RbAmpSensorClass.SCT_013)
dev.set_ct_model_ch(0, 1)
dev.set_ct_model_ch(1, 1) # ch0 is overwritten with the same value
dev.set_ct_model_ch(2, 1)The single-parameter dev.set_ct_model(code) remains for backward
compat with UI1 modules (it applies to channel 0). On
multi-channel modules it is equivalent to
dev.set_ct_model_ch(0, code).
On v1.0/v1.1 firmware (REG_VERSION < 0x03) the per-channel opcodes
CMD_SET_CT_MODEL_CHndo not exist —dev.set_ct_model_ch(channel, code)raisesRbAmpVersionErrorwithout writing. Use the single-parameterdev.set_ct_model(code), which writes to channel 0 via the legacy path.
Advanced setup: two clamps of different ratings on one wire
⚙ An advanced pattern, not a basic one. This section describes an optional technique for improving resolution at low currents. For most installations, a single clamp matched to the load range is sufficient. Use dual-CT only if you have a specific accuracy requirement at currents < 1 A.
When it applies
- Multi-channel UI2 / UI3 modules on v1.2+ firmware.
- The same wire needs to be measured both for small loads (≤ 1 A) and for peak events (≥ 5 A) with equal quality.
- A typical example: an apartment service entrance with 50–100 W standby during the day, and a kettle or electric stove drawing 3+ kW in the evening.
The idea
Two SCT-013 clamps of different ratings are installed on the same wire:
- Channel 0 — the small clamp (e.g., SCT-013-005, 5 A): sees small currents with better resolution and a lower noise floor.
- Channel 1 — the large clamp (e.g., SCT-013-030 or higher): handles currents above the small clamp's overload point without saturation.
The master decides which channel to use based on the current value — while the small clamp is in its linear range, its reading is more accurate; above that, it switches to the large one.
Configuration (descending order — mandatory)
The sensor class first, once, then the models in order from
the highest channel to the lowest — otherwise the legacy
REG_CT_MODEL side effect overwrites channel 0 with the value of
the last call (see the warning in the previous section, "Modules
with multiple current channels").
dev.set_sensor_class(RbAmpSensorClass.SCT_013) # once
# First channel 1 (the large clamp), then channel 0 (the small one) —
# so the final ch0 value is correct.
dev.set_ct_model_ch(1, 3) # ch1 = SCT-013-030 (0..30 A)
dev.set_ct_model_ch(0, 1) # ch0 = SCT-013-005 (0..5 A)Final state: ch0 = SCT-013-005, ch1 = SCT-013-030. ✓
Aggregation logic on the master side
The simplest pattern is to switch on a threshold:
import math
def read_combined_current(dev):
"""Read the combined current — picks low-CT when in its linear range,
otherwise falls back to the high-CT.
"""
i_low = dev.read_current(0) # the small clamp
i_high = dev.read_current(1) # the large clamp
# While the small clamp is far from saturation, it gives better
# accuracy at low currents. Switch to the large one as it
# approaches its overload point.
#
# The 4.5 A threshold for SCT-013-005 is PROVISIONAL; the exact
# value will be determined by bench validation (see below, re IP-010).
# Behavior near the threshold is a matter of measurement, not estimate.
if not math.isnan(i_low) and i_low < 4.5:
return i_low
return i_high📷 An installation diagram is expected. Two clamps on one wire are physically possible on most household-gauge cables, but they need a little room in the panel. A detailed diagram — including the arrow orientation of both clamps and the allowable distances between them — will appear here as it is prepared.
⚙ Bench validation. The exact figures for the dual-CT pattern (behavior near the threshold, temperature drift, the divergence of the two clamps in the overlapping range) are established by the IP-010 measurement program (the successor to IP-001). Until it is complete, treat dual-CT as a pilot pattern; for critical applications, a single clamp matched to the upper end of the load range is preferable.
Approaches to improving low-current sensitivity
If your load has a wide dynamic range (for example, 1 W router standby vs. a 2000 W water heater on the same outlet), a single clamp sized for the upper limit loses the lower currents in the noise.
Three strategies, in increasing order of complexity:
- Size the CT to the maximum, not "with margin". The most common mistake is putting an SCT-013-100 (100 A) on a household outlet with typical consumption of 0.5–10 A. The signal sits in the bottom 1–10% of the ADC — where noise becomes comparable to the signal. For a household scenario (a 16 A outlet) SCT-013-030 is optimal; for connecting a single device (≤ 5 A), SCT-013-005.
- Dual-CT topology (requires a UI2/UI3 SKU): a small clamp for the low range + a large one for the high range, with the master choosing by threshold. See the "Dual-CT topology" section above — the pattern is a pilot, and the numbers are being refined by the IP-010 program.
- Bench calibration of the noise floor (factory-side): IP-001
characterizes the noise floor on a test bench; the results are
baked into the firmware's calibration array. On the user side,
nothing needs to be done beyond
set_sensor_class()+set_ct_model(). Until the program is complete, the specific low-current accuracy numbers are not published.
What's next
- 04 · Hardware connection — physical connection of the clamp, arrow orientation, L/N polarity
- 05 · Quickstart — a full first-light script for both backends
- 06 · Examples — working scenarios for different loads
- 10 · Troubleshooting — what to do if the readings are strange (negative PF, unstable I, etc.)