06 · Examples

This chapter opens with the flagship scenarios — the real-world deployment patterns the package was designed for (mains + N sub-loads on a single bus via RbAmpFleet, GC-synchronized snapshots, multi-channel mixed-CT via configure_channels()). These are followed by single-module scenarios — from a minimal "hello world" to a production deployment.

Most scenarios have parallel implementations in MicroPython (under examples_upy/) and CPython (under examples_cpython/). The code below is the distilled core logic; the full versions live in the corresponding example files.

# Scenario MicroPython CPython
1 Mains + N sub-loads — the 80% canon (composition) (composition)
2 Provisioning workflow (virgin → fleet) (composition) (composition)
3 Multi-channel mixed-CT (I3, different models) (composition) (composition)
4 Fleet GC sync — billing-grade synchrony (composition) (composition)
5 Quick read (single module) 01_quick_read.py 01_quick_read.py
6 Period meter + local display 02_oled_period.py 02_period_meter.py
7 Monitoring 3 modules (legacy sequential) 03_multi_module.py 03_multi_module_broadcast.py
8 UI variant + per-channel MQTT 04_mqtt.py 04_mqtt_publisher.py
9 Bidirectional metering on the master side 07_bidirectional_energy.py 05_bidirectional_energy.py
10 Whole-home energy balance (multi-module + MQTT) 08_home_energy_balance.py 07_home_energy_balance.py
11 Event detection logging (EMA) 09_event_detection_logger.py (composition)
12 Local rotating logger (with open(...) flash-based) 08_rotating_file_logger.py
13 Battery-powered deep-sleep logger 06_deep_sleep.py (not applicable)
14 Async streaming via stream_period 05_async_streaming.py (asyncio equivalent)

Scenarios 1–4 are the flagship scenarios, built around the package's canonical deployment. Their code uses RbAmpFleet and is validated on bench hardware (UI1+I2+I3 heterogeneous fleet). Scenarios 5–14 are single-module and compose patterns. Scenario 7 is the legacy sequential per-module latch without the fleet API, kept for comparison and as a migration path.

All scenarios assume that the sensor class and CT model are already configured via dev.set_sensor_class() + dev.set_ct_model() (or in a single dev.configure_channels() call for multi-channel). See 05 · Quickstart Step 4. This is done once at installation time — the settings are persisted to the module's flash and survive a reset.

🛑 Runnable examples for flagship 1-4 — pending. The lib-python session deferred Task #16 (new example files for the v1.3 RbAmpFleet/LABEL/two-phase-addr surface). The skeletons in this chapter are valid and use the canonical API surface (per the lib-python v13-doc-info package); the full runnable .py files will land in a separate lib-side commit.


Scenario 1 — Mains + N sub-loads (the 80% canon): integrated metering system

Goal: the package's canonical deployment — a cohesive metering system on a heterogeneous fleet, closed inside a single loop (discover → configure → arm GC → loop[gc_latch + check_sync + poll_all + totals]).

Hardware (HW-validated on the Fix-A fleet): UI1@0x50 + I2@0x51 + I3@0x52; ~0.58 A load; external 4.7 kΩ pull-up.

Code (CPython)

python
import time
from smbus2 import SMBus
from rbamp import RbAmpFleet, RbAmpSensorClass
def configure_one(dev):
    variant = dev.read_variant()
    if variant == 1:                                    # UI1 mains
        dev.set_sensor_class(RbAmpSensorClass.SCT_013)
        dev.set_ct_model_ch(0, 3)                       # SCT-013-030
        dev.save_user_config()
    elif variant == 5:                                  # I2
        dev.configure_channels(RbAmpSensorClass.SCT_013, [1, 3])
    elif variant == 6:                                  # I3
        dev.configure_channels(RbAmpSensorClass.SCT_013, [1, 3, 6])
with SMBus(1) as bus:
    fleet = RbAmpFleet(bus)
    # 1) discover
    added = fleet.scan(match_product=True)
    print(f"fleet_scan: {added} module(s), {len(fleet.excluded)} excluded")
    # 2) configure per-module (mixed-CT on the sub-meters)
    for dev in fleet:
        configure_one(dev)
    # 3) arm GC across the whole fleet
    gc_ok = fleet.enable_gc_all(group=0)
    print(f"enable_gc_all → {gc_ok}/{len(fleet)} armed")
    # 4) loop: gc_latch → check_sync → poll_all → totals
    while True:
        tick = fleet.gc_latch(group=0)                  # auto-increment
        sync = fleet.check_sync(expected_tick=tick)
        n_missed = sum(1 for s in sync if not s.in_sync)
        snaps = fleet.poll_all()
        n_ok = sum(1 for snap, info in snaps if info.ok)
        p_total = fleet.total_power()
        e_total = fleet.total_energy_wh()
        n_total = len(fleet)
        print(f"ITER {tick}: GC {n_total - n_missed}/{n_total} in_sync | "
              f"poll n_ok={n_ok}/{n_total} | "
              f"P_total={p_total:.1f} W  E_total={e_total:.3f} Wh")
        time.sleep(1.0)

MicroPython version

Identical to the CPython version, with the bus initialization swapped out:

python
from machine import I2C, Pin
bus = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
fleet = RbAmpFleet(bus)
# ... the rest is the same ...

Bench output (HW-validated, ~0.58 A load)

text
fleet_scan: 3 module(s), 0 excluded
  [0] @0x50  channels=1  voltage=yes   (mains meter: U + 1 current)
  [1] @0x51  channels=2  voltage=no    (2-channel current sub-meter)
  [2] @0x52  channels=3  voltage=no    (3-channel current sub-meter)
configure_channels(2ch) → mirrors [1 2 -]
configure_channels(3ch) → mirrors [1 2 3]
enable_gc_all → 3/3 armed
ITER N: GC 3/3 in_sync | poll n_ok=3/3 | P_total≈1260 W  E_total: 0 → 27.84 Wh
   @0x50  V=232.6  I=[5.79]                f=50.00
   @0x51  V= —     I=[11.58, 3.87]         f=50.00
   @0x52  V= —     I=[ 3.84, 2.55, 5.84]   f=50.00  (3rd input unused)

The bench figures come from uncalibrated DUTs — they illustrate the shape of the data, not metrological accuracy. The package's Wh accounting is mathematically exact (bench measure: rel_err = 0.0000%).

Notes for use

  • One synchronized loop — the entire system. Each tick: a single gc_latch() → all modules atomically start the period latch (check_sync = 3/3) → one poll_all() → aggregation.
  • total_power() in a heterogeneous fleet. UI1 reports active power; I2/I3 are current-only and contribute 0. In the 80% canon, total_power ≈ the power of the mains module.
  • Energy (Wh) — master wall-clock. The package integrates each period using time.monotonic() (CPython) or time.ticks_diff() (MicroPython), not the chip latch_ms. See 10 · Troubleshooting, the section "latch_ms reads about 27% low".
  • MISS-resilient. If one module drops out, poll_all() marks info.ok = False and continues; check_sync() marks RbAmpFleetSync.reachable = False.
  • Per-channel disaggregation. Through poll_all() the master sees all current channels (1+2+3 = 6 on our bench fleet) at once.

Scenario 2 — Provisioning workflow (virgin → fleet)

Goal: move a new module off its factory address 0x50 onto a working address and join it to an existing fleet, persisting the configuration to flash.

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpFleet, RbAmpSensorClass, RbAmpError
def provision_new_module(bus, fleet, desired_addr, label=None):
    """
    PRECONDITION: exactly one virgin on the bus at 0x50.
    MUST be one-virgin-at-a-time — see ch.04 + ch.10.
    """
    try:
        # 1) handle on the factory-default 0x50
        dev = RbAmp(bus, 0x50)
        dev.begin()
        # 2) two-phase address commit
        dev.prepare_address_change(desired_addr)   # arms candidate, 5 s window
        dev.commit_address_change()                # magic + commit + reset
        time.sleep(0.3)                             # boot window
        # 3) optional config — label + sensor class + CT model
        if label:
            dev.set_label(label)
        dev.set_sensor_class(RbAmpSensorClass.SCT_013)
        dev.set_ct_model_ch(0, 3)                  # SCT-013-030
        dev.save_user_config()                      # persist
        # 4) add to the fleet
        fleet.add(dev)
        print(f"provisioned virgin → 0x{desired_addr:02X} (+saved)")
        return dev
    except RbAmpError as e:
        print(f"provision @0x{desired_addr:02X} failed: {e}")
        return None
with SMBus(1) as bus:
    fleet = RbAmpFleet(bus)
    fleet.scan()
    provision_new_module(bus, fleet, 0x52, label="kitchen")

Bench output (HW-validated success path)

text
before: present(0x50)=yes  present(0x52)=no
virgin @0x50: variant=3-channel, channels=3
prepare_address_change(0x52) OK
commit_address_change() OK (lib log: "provisioned virgin → 0x52 (+saved)")
post:   handle now answers @0x52, is_provisioned()=True
after:  present(0x50)=no   present(0x52)=yes

Failure paths

Exception Condition Recovery
RbAmpIOError Nobody answers at 0x50 Check VCC/I2C; bus-scan (10 · Troubleshooting)
RbAmpIOError + conflict A conflict on 0x50/desired_addr Discipline violation — more than one virgin. Power-cycle + disconnect all but one
RbAmpTimeoutError The 5-second arm window expired before commit_address_change Retry (the lib guarantees the arm state is cleared via try/finally)
RbAmpParamError desired_addr outside 0x08..0x77 Use a valid 7-bit address

A static RbAmpFleet.provision(bus, addr, save_config, ...) is on the roadmap (S6 territory; ETA after the release cycle). Until then, use the manual workflow above with prepare_address_change + commit_address_change + fleet.add().


Scenario 3 — Multi-channel mixed-CT (I3, a different model per channel)

Goal: demonstrate configure_channels() on an I3 — three channels with different CT models (ch0=SCT-013-005, ch1=SCT-013-030, ch2=SCT-013-020) in a single terminal flash cycle, and confirm persistence across a reboot.

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpSensorClass, RbAmpParamError
with SMBus(1) as bus:
    dev = RbAmp(bus, 0x52)                          # I3 sub-meter
    dev.begin()
    # (a) Configure — three CT models in one call
    models = [1, 3, 6]
    # 1=SCT-013-005 (5A), 3=SCT-013-030 (30A), 6=SCT-013-020 (20A)
    t0 = time.monotonic()
    try:
        dev.configure_channels(RbAmpSensorClass.SCT_013, models)
    except RbAmpParamError as e:
        print(f"configure rejected: {e}")
        raise
    t1 = time.monotonic()
    print(f"configure_channels latency = {(t1-t0)*1000:.0f} ms")
    # (b) Verify the mirror via registers 0x51 / 0x52 / 0x53 (RAM)
    m = [dev.read_ct_model_ch(ch) for ch in range(3)]
    print(f"applied: {m}  (expected [1, 3, 6])")
    # (c) Persist verify — reset + re-read the mirror after boot
    dev.reset()
    time.sleep(0.3)
    m = [dev.read_ct_model_ch(ch) for ch in range(3)]
    print(f"after reboot: {m}")

Bench output (HW-validated on the Fix-A I3)

text
configure_channels(SCT_013, [1, 3, 6]) = OK
  → read_ct_model_ch 0/1/2 = [1, 3, 6]   raw mirror 0x51/52/53 = [01 03 06]
  → ch0 NOT clobbered (Fix-A canon: bind order-independent)
configure_channels latency ≈ 1400 ms
after reboot: [1, 3, 6]  (persisted through reset)

The "single SAVE" property — why it matters

configure_channels() performs a single terminal CMD_SAVE_USER_CONFIG. The alternative (per-channel set_ct_model_ch + save_user_config() after each one) is three flash erase + write cycles.

Bench latency comparison (on the same I3):

Approach Latency Flash cycles
configure_channels(...) — 1 SAVE ~1.4 s 1
(set_ct_model_ch + save_user_config) ~3.5 s 3

3× slower — (~2.5×) × ~700 ms. The key point is the 3× wear-cycle difference on the same flash page.

Valid codes (bench-characterized). SCT-013 on the current bench: {1, 2, 3, 4, 6}. Codes 5 (SCT-013-100) and 7 (SCT-013-060) are uncharacterised → RbAmpParamError pre-bus (no I²C operation).


Scenario 4 — Fleet GC sync (billing-grade synchrony)

Goal: demonstrate an atomic latch across the whole fleet in a single I²C General-Call frame. Unlike a sequential per-module latch_period(), GC synchronizes all modules in one bus transaction.

python
import time
from smbus2 import SMBus
from rbamp import RbAmpFleet
with SMBus(1) as bus:
    fleet = RbAmpFleet(bus)
    fleet.scan()
    # Step 1: enable GC on every module in the fleet
    gc_ok = fleet.enable_gc_all(group=0)
    print(f"GC armed: {gc_ok}/{len(fleet)}")
    # Steps 2-3: loop with broadcast latch + witness check
    for round_idx in range(10):
        tick = fleet.gc_latch(group=0)             # auto-increment tick
        sync = fleet.check_sync(expected_tick=tick)
        n_in_sync = sum(1 for s in sync if s.in_sync)
        print(f"round {round_idx}  tick={tick}  in_sync={n_in_sync}/{len(fleet)}")
        time.sleep(0.1)

Bench output (HW-validated)

text
enable_gc_all → 3/3 modules armed
round 0   tick=0   in_sync=3/3
round 1   tick=1   in_sync=3/3
...
round 9   tick=9   in_sync=3/3      skew=0 (validated at tick=0xABCD)

When to use GC sync

  • Billing-grade synchrony. A sequential per-module latch on those same 3 modules accumulates 100-300 µs per module × N of skew. GC delivers skew = 0 by bench measurement.
  • Large fleet. The gap between "sequential N × round_trip" and "a single GC frame" grows linearly.

Witness via check_sync(): verifies that all modules actually received the GC frame. If a module was busy with a boot / SAVE cycle, RbAmpFleetSync.reachable = False.

Precondition. GC must be enabled on each module (fleet.enable_gc_all() or per-device dev.enable_gc(True)). A fresh module with factory defaults does not accept GC — by design, a guard against an accidental broadcast on a bring-up bus.


Scenario 5 — Quick read (single module)

Goal: print U / I / P / PF / frequency once per second. The same "hello world" you wrote in 05 · Quickstart, but using dev.read_all() — a single-shot read of the whole RT block into one RbAmpSnapshot structure.

CPython version

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpError
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    while True:
        try:
            s = dev.read_all()
        except RbAmpError as e:
            print("read fail:", e)
            time.sleep(1)
            continue
        line = f"U={s.voltage:.1f} V  f={s.frequency} Hz   "
        for ch in range(s.channels):
            line += f"I{ch}={s.current[ch]:.2f}A  P{ch}={s.power[ch]:.1f}W  "
        print(line)
        time.sleep(1)

MicroPython version

python
import time
from machine import I2C, Pin
from rbamp import RbAmp, RbAmpError
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
with RbAmp(i2c, 0x50) as dev:
    while True:
        try:
            s = dev.read_all()
        except RbAmpError as e:
            print("read fail:", e)
            time.sleep(1)
            continue
        print("U={:.1f} V  f={} Hz".format(s.voltage, s.frequency))
        for ch in range(s.channels):
            print("  I{}={:.2f}A  P{}={:.1f}W".format(
                ch, s.current[ch], ch, s.power[ch]))
        time.sleep(1)

What happens on the bus: dev.read_all() on a UI3 performs ~53 byte transactions (13 float values × 4 bytes + 1 frequency byte). At 50 kHz with retry headroom, that is on the order of 25-30 ms. If you don't need all the values, use the per-property accessors (dev.voltage, dev.read_current(ch)).


Scenario 6 — Period meter + local display

Goal: a Wh counter, updated once per minute, on a local display. On MicroPython — an SSD1306 OLED on the same I²C bus. On CPython — text output to stdout (you can wire up a character LCD over GPIO, or use MQTT/HA publishing — see Scenario 8 (MQTT/HA)).

MicroPython version (SSD1306 OLED)

python
import time
from machine import I2C, Pin
from ssd1306 import SSD1306_I2C
from rbamp import RbAmp, RbAmpStaleError, RbAmpSensorClass
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
oled = SSD1306_I2C(128, 64, i2c)   # OLED on the same bus, addr 0x3C
with RbAmp(i2c, 0x50) as dev:
    snapshots_ok = 0
    snapshots_bad = 0
    while True:
        time.sleep(60)
        try:
            snap = dev.read_period_snapshot()
            snapshots_ok += 1
        except RbAmpStaleError:
            snapshots_bad += 1
            continue
        oled.fill(0)
        oled.text("rbAmp Energy Meter", 0, 0)
        oled.text("{:.1f} W".format(snap.avg_p[0]), 0, 16, 1)
        oled.text("Wh: {:.4f}".format(dev.energy.wh(0)), 0, 32)
        oled.text("ok={} bad={}".format(snapshots_ok, snapshots_bad), 0, 48)
        oled.show()

CPython version (period meter without a display)

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpStaleError
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    snapshots_ok = 0
    snapshots_bad = 0
    while True:
        time.sleep(60)
        try:
            snap = dev.read_period_snapshot()
            snapshots_ok += 1
        except RbAmpStaleError:
            snapshots_bad += 1
            print("stale snapshot — skipping")
            continue
        print(f"P = {snap.avg_p[0]:.2f} W   "
              f"Wh = {dev.energy.wh(0):.4f}   "
              f"ok={snapshots_ok} bad={snapshots_bad}   "
              f"dt={snap.master_dt_ms} ms")

Handling stale snapshots. dev.read_period_snapshot() raises RbAmpStaleError if the module hasn't managed to prepare a new snapshot by read time. The package still records the master timestamp internally — the next successful snapshot won't be double-counted over the interval. A standard Python try/except pattern.


Scenario 7 — Monitoring 3 modules (legacy sequential) on one bus

Goal: poll 3 modules at addresses 0x50 / 0x51 / 0x52. The canonical pattern for v1 firmware — sequential per-device LATCH + a shared settle + per-device read_period_snapshot(skip_latch=True). Inter-device skew at 100 kHz: ~1 ms per device, < 0.2 % of a 60-second period.

The RbAmp.broadcast_latch(bus) function (and its preferred broadcast_latch_group(bus, group, tick) form) requires GC to be opted in on each module: capability bit CAP_GC_LATCH set + FLEET_CONFIG.bit0 enabled (default OFF, persisted via CMD_SAVE_USER_CONFIG + reset — done by dev.enable_gc(True) or fleet.enable_gc_all()). On a legacy module without the capability, the call falls back to a sequential per-device latch. See 09 · API Reference for details.

CPython version

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpStaleError
ADDRS = [0x50, 0x51, 0x52]
with SMBus(1) as bus:
    devs = [RbAmp(bus, addr) for addr in ADDRS]
    for dev in devs:
        dev.begin()
    while True:
        time.sleep(60)
        # Phase 1: sequential LATCH on each device, measure the skew
        t_start = time.monotonic()
        for dev in devs:
            dev.latch_period()
        sync_ms = (time.monotonic() - t_start) * 1000
        # Phase 2: a single shared settle for all 3 modules
        time.sleep(0.050)
        # Phase 3: read the snapshots with skip_latch=True
        print(f"sync_ms={sync_ms:.1f}")
        for i, dev in enumerate(devs):
            try:
                snap = dev.read_period_snapshot(settle_ms=0, skip_latch=True)
            except RbAmpStaleError:
                continue
            print(f"  mod{i} 0x{ADDRS[i]:02X}  P={snap.avg_p[0]:.0f} W  "
                  f"Wh={dev.energy.wh(0):.3f}")

MicroPython version

python
import time
from machine import I2C, Pin
from rbamp import RbAmp, RbAmpStaleError
ADDRS = [0x50, 0x51, 0x52]
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
devs = [RbAmp(i2c, addr) for addr in ADDRS]
for dev in devs:
    dev.begin()
while True:
    time.sleep(60)
    t_start = time.ticks_ms()
    for dev in devs:
        dev.latch_period()
    sync_ms = time.ticks_diff(time.ticks_ms(), t_start)
    time.sleep_ms(50)
    print("sync_ms=", sync_ms)
    for i, dev in enumerate(devs):
        try:
            snap = dev.read_period_snapshot(settle_ms=0, skip_latch=True)
        except RbAmpStaleError:
            continue
        print("  mod{} 0x{:02X}  P={:.0f} W  Wh={:.3f}".format(
            i, ADDRS[i], snap.avg_p[0], dev.energy.wh(0)))

Scenario 8 — UI variant + per-channel MQTT

Goal: a UI3 module with 3 CT clamps on three independent lines. Per-channel Wh counters, published to MQTT once per minute. Shows that dev.energy.wh(ch) works on each channel independently — no manual total_wh[3] array on the master side is needed.

CPython (via paho-mqtt)

python
import time, json
from smbus2 import SMBus
import paho.mqtt.client as mqtt_client
from rbamp import RbAmp, RbAmpStaleError, RbAmpSensorClass
CH_NAMES = ["main", "heatpump", "lights"]
mqtt = mqtt_client.Client("rbamp-ui3")
mqtt.connect("192.168.1.10", 1883, keepalive=60)
mqtt.loop_start()
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    while True:
        time.sleep(60)
        try:
            snap = dev.read_period_snapshot()
        except RbAmpStaleError:
            continue
        for ch in range(dev.channels):
            payload = json.dumps({
                "power":  round(snap.avg_p[ch], 1),
                "energy": round(dev.energy.wh(ch), 4),
            })
            mqtt.publish(f"rbamp/{CH_NAMES[ch]}/state",
                         payload, qos=1, retain=True)

MicroPython (via umqtt.simple)

python
import time, ujson
from machine import I2C, Pin
from umqtt.simple import MQTTClient
from rbamp import RbAmp, RbAmpStaleError, RbAmpSensorClass
CH_NAMES = [b"main", b"heatpump", b"lights"]
mqtt = MQTTClient(b"rbamp-ui3", b"192.168.1.10",
                  port=1883, keepalive=60)
mqtt.connect()
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
with RbAmp(i2c, 0x50) as dev:
    while True:
        time.sleep(60)
        try:
            snap = dev.read_period_snapshot()
        except RbAmpStaleError:
            continue
        for ch in range(dev.channels):
            payload = ujson.dumps({
                "power":  round(snap.avg_p[ch], 1),
                "energy": round(dev.energy.wh(ch), 4),
            })
            topic = b"rbamp/" + CH_NAMES[ch] + b"/state"
            mqtt.publish(topic, payload.encode(), qos=1, retain=True)

On MicroPython, umqtt.simple is a synchronous blocking client. For an async variant, use mqtt_as (an asyncio MQTT client) — see also Scenario 10.

For full HA Auto-discovery on top of this pattern, see 07 · DIY integrations.


Scenario 9 — Bidirectional metering on the master side

Goal: split signed instantaneous power into gross-consume and gross-export. Use this pattern on the BASIC tier, where the firmware clips negative values in snap.avg_p[ch] (period-averaged power) — sample dev.read_power(0) (instantaneous power, signed on all tiers) at 5 Hz on the master side and bucket it yourself.

CPython version

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpIOError
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    consume_wh = 0.0
    export_wh  = 0.0
    t_prev = time.monotonic()
    while True:
        time.sleep(0.2)   # 5 Hz, matches the RT cadence
        t_now = time.monotonic()
        dt_s  = t_now - t_prev
        t_prev = t_now
        try:
            p = dev.read_power(0)
        except RbAmpIOError:
            continue
        dwh = p * dt_s / 3600.0
        if p >= 0:
            consume_wh += dwh
        else:
            export_wh  += -dwh
        # Print once per second
        if int(t_now) % 5 == 0:
            print(f"P={p:.1f} W   "
                  f"cons={consume_wh:.4f} Wh  exp={export_wh:.4f} Wh  "
                  f"net={consume_wh - export_wh:.4f} Wh")

MicroPython version

python
import time
from machine import I2C, Pin
from rbamp import RbAmp, RbAmpIOError
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
with RbAmp(i2c, 0x50) as dev:
    consume_wh = 0.0
    export_wh  = 0.0
    t_prev = time.ticks_ms()
    while True:
        time.sleep_ms(200)
        t_now = time.ticks_ms()
        dt_s  = time.ticks_diff(t_now, t_prev) / 1000
        t_prev = t_now
        try:
            p = dev.read_power(0)
        except RbAmpIOError:
            continue
        dwh = p * dt_s / 3600.0
        if p >= 0:
            consume_wh += dwh
        else:
            export_wh  += -dwh

On future STANDARD / PRO firmware tiers (planned for a future tier release) the period accumulator dev.energy.wh(0) will already return a signed net balance — this master-side split is only needed for separate gross-consume / gross-export reporting.


Scenario 10 — Whole-home energy balance

Goal: 3 modules — mains (bidirectional), solar (generation only), loads (UI3 for per-appliance). A combined dashboard is published once per minute.

python
import time, json
from smbus2 import SMBus
import paho.mqtt.client as mqtt_client
from rbamp import RbAmp, RbAmpStaleError, RbAmpSensorClass
with SMBus(1) as bus:
    mains = RbAmp(bus, 0x50)   # bidirectional mains
    solar = RbAmp(bus, 0x51)   # generation only
    loads = RbAmp(bus, 0x52)   # UI3 — per-appliance
    devs = [mains, solar, loads]
    for d in devs:
        d.begin()
    mqtt = mqtt_client.Client("home-balance")
    mqtt.connect("192.168.1.10", 1883, keepalive=60)
    mqtt.loop_start()
    while True:
        time.sleep(60)
        # Sequential LATCH + shared settle (the Scenario 7 pattern — legacy sequential)
        for d in devs:
            d.latch_period()
        time.sleep(0.050)
        try:
            sm = mains.read_period_snapshot(settle_ms=0, skip_latch=True)
            ss = solar.read_period_snapshot(settle_ms=0, skip_latch=True)
            sl = loads.read_period_snapshot(settle_ms=0, skip_latch=True)
        except RbAmpStaleError:
            continue
        payload = {
            "mains":  round(mains.energy.wh(0), 3),
            "solar":  round(solar.energy.wh(0), 3),
            "hp":     round(loads.energy.wh(0), 3),
            "ac":     round(loads.energy.wh(1), 3),
            "ev":     round(loads.energy.wh(2), 3),
        }
        mqtt.publish("home/energy/balance",
                     json.dumps(payload), qos=1, retain=True)

For an explicit gross-consume / gross-export split on the mains, combine this with the Scenario 5 pattern (a separate 5 Hz loop on mains.read_power(0) in a background threading.Thread on CPython, or uasyncio.create_task on MicroPython).


Scenario 11 — Event detection logging (EMA)

Goal: on every 200 ms RT window, compare instantaneous power against an exponential moving average. Log significant deviations — loads such as a microwave, kettle, or hair dryer "appear" in the log as a turn-on / turn-off event.

python
import time
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpIOError
EMA_ALPHA = 0.05
EVENT_THRESHOLD_W = 200.0
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    try:
        p_ema = dev.read_power(0)   # seed so the first read isn't an event
    except RbAmpIOError:
        p_ema = 0.0
    while True:
        time.sleep(0.2)
        try:
            p = dev.read_power(0)
        except RbAmpIOError:
            continue
        delta = p - p_ema
        p_ema = (1 - EMA_ALPHA) * p_ema + EMA_ALPHA * p
        if abs(delta) > EVENT_THRESHOLD_W:
            action = "TURN_ON" if delta > 0 else "TURN_OFF"
            print(f"{time.time():.0f}  {action}  delta={delta:.0f} W  "
                  f"P={p:.0f} W  EMA={p_ema:.0f}")

On MicroPython — the same substitutions: time.sleeptime.sleep_ms, time.time()time.time() (available on most ports) or time.ticks_ms().

Combine with the MQTT publishing from Scenario 8 for HA-side automations.


Scenario 12 — Local rotating logger (CPython)

Goal: write the period snapshot to a rotating CSV file once per minute via the standard logging.handlers.RotatingFileHandler. Useful for standalone deployments without WiFi / MQTT, or as a buffer for deferred cloud sync.

python
import time, logging
from logging.handlers import RotatingFileHandler
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpStaleError
log = logging.getLogger("rbamp.csv")
log.setLevel(logging.INFO)
handler = RotatingFileHandler("rbamp.csv", maxBytes=1_000_000, backupCount=5)
handler.setFormatter(logging.Formatter("%(asctime)s,%(message)s",
                                       datefmt="%Y-%m-%dT%H:%M:%S"))
log.addHandler(handler)
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    while True:
        time.sleep(60)
        try:
            snap = dev.read_period_snapshot()
        except RbAmpStaleError:
            log.warning("stale")
            continue
        log.info(f"{snap.avg_p[0]:.1f},{dev.energy.wh(0):.4f},"
                 f"{snap.master_dt_ms}")

On MicroPython the standard logging.handlers is absent — for a local log, use a simple with open("log.csv", "a") + manual rotation via os.stat() + os.rename(). See the full example in examples_upy/09_event_detection_logger.py.

For deferred cloud sync (log locally, send once per hour) — see the "Hybrid: local storage + sync" section in 08 · Cloud integrations.


Scenario 13 — Battery-powered deep-sleep logger (MicroPython only)

Goal: an ESP32 (MicroPython) wakes once every 10 minutes, takes one period latch, publishes over WiFi+MQTT, and goes back into deep-sleep. Energy is persisted in RTC memory across sleep cycles.

Important about deep-sleep and v1.0/v1.1 firmware. On the current firmware, dev.begin() issues a CMD_LATCH_PERIOD primer that resets the firmware's period accumulator. This means that after a deep-sleep wake you can't simply call read_period_snapshot() by default — that call would re-latch and return near-zero data for the ~50 ms since the primer. The correct pattern below uses skip_latch=True to read the data accumulated over the sleep interval, and the known sleep duration (machine.deepsleep(SLEEP_MS)) as dt — time.ticks_ms() after wake may be an unreliable source.

python
import time, machine
from machine import I2C, Pin
from rbamp import RbAmp, RbAmpSensorClass
# Stub for publishing. Replace with real WiFi+MQTT logic —
# see Scenario 8 (mqtt_publisher) for a template. In the deep-sleep
# scenario the WiFi stack is brought up/torn down on every wake, which
# eats up the bulk of the energy budget.
def publish_via_wifi(power_w, total_wh, dt_s):
    print("P=%.1f W  Wh=%.4f  dt=%.1f s" % (power_w, total_wh, dt_s))
SLEEP_MS = 10 * 60 * 1000             # 10 minutes — fixed interval
RTC_MAGIC = b"\xCA\xFE\xFE\xED"
# RTC slow-memory: retained between deep-sleep wakes
rtc = machine.RTC()
state = rtc.memory()                  # bytes; empty on cold boot
def save_state(magic, wh_total, primer_done):
    # Simple layout: 4 bytes magic + 8 bytes float wh + 1 byte primer_done
    import struct
    rtc.memory(magic + struct.pack("dB", wh_total, 1 if primer_done else 0))
def load_state():
    import struct
    if len(state) < 4 + 8 + 1 or state[:4] != RTC_MAGIC:
        return False, 0.0, False
    wh_total, primer_done_byte = struct.unpack("dB", state[4:4+9])
    return True, wh_total, bool(primer_done_byte)
valid, rtc_total_wh, primer_done = load_state()
if not valid:
    rtc_total_wh = 0.0
    primer_done = False
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
with RbAmp(i2c, 0x50) as dev:    # __enter__ automatically calls begin() — the LATCH primer
    dev.energy.disable()         # the master owns Wh persistence itself
    if not primer_done:
        # First wake: the primer just latched "dirty" data.
        # Save the flag and go straight back to sleep — the next wake in
        # SLEEP_MS will get a full accumulator over the interval.
        save_state(RTC_MAGIC, rtc_total_wh, primer_done=True)
        machine.deepsleep(SLEEP_MS)
    # skip_latch=True reads what the begin() primer latched —
    # that is, the accumulator over the elapsed sleep interval.
    snap = dev.read_period_snapshot(settle_ms=0, skip_latch=True)
    # Use the KNOWN sleep duration as dt
    dt_s = SLEEP_MS / 1000
    rtc_total_wh += snap.avg_p[0] * dt_s / 3600.0
    publish_via_wifi(snap.avg_p[0], rtc_total_wh, dt_s)  # stub
    save_state(RTC_MAGIC, rtc_total_wh, primer_done=True)
machine.deepsleep(SLEEP_MS)

The full sketch (with WiFi setup, MQTT publish, RTC magic-marker guards) is in examples_upy/06_deep_sleep.py.

🛣 Roadmap. A future package version is expected to add dev.warm_open() — a lightweight context manager without the CMD_LATCH_PERIOD primer, which will make it easier to read read_period_snapshot() by default after a deep-sleep wake. Until then, the pattern above (skip_latch=True + known SLEEP_MS) is canonical.

Energy budget (ESP32-WROOM on a 2000 mAh Li-ion, 10-minute interval):

  • Active cycle: ~3 s (WiFi + MQTT + I²C) at ~80 mA → ~0.07 mAh per wake
  • Sleep: ~10 µA (RTC + retained domains)
  • ~10 mAh per day → 2000 mAh lasts ~6 months

CPython hosts (Raspberry Pi etc.) typically run off a 24/7 power supply — deep-sleep does not apply. For CPython battery operation, see 08 · Cloud integrations, the section on power consumption and systemd suspend.


Scenario 14 — Async streaming via stream_period (Python-only feature)

Goal: integration into an existing asyncio / uasyncio event loop. The package provides an async generator dev.stream_period(interval_s=...) that encapsulates the periodic latch + automatic stale handling.

CPython (via asyncio + paho-mqtt-asyncio or flat)

python
import asyncio
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpSensorClass
async def main():
    with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
        # Once per minute, skip_stale=True (default) — stale snapshots are
        # automatically skipped without raising RbAmpStaleError
        async for snap in dev.stream_period(interval_s=60.0):
            print(f"P={snap.avg_p[0]:.2f} W,  Wh={dev.energy.wh(0):.4f}")
asyncio.run(main())

MicroPython (via uasyncio)

python
import uasyncio as asyncio
from machine import I2C, Pin
from rbamp import RbAmp, RbAmpSensorClass
async def reader(dev):
    async for snap in dev.stream_period(interval_s=60.0):
        print("P={:.2f} W,  Wh={:.4f}".format(snap.avg_p[0], dev.energy.wh(0)))
async def main():
    i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
    with RbAmp(i2c, 0x50) as dev:
        # Run the reader + other async tasks in parallel
        await asyncio.gather(
            reader(dev),
            # other_async_task(),
        )
asyncio.run(main())

stream_period(interval_s=, skip_stale=) parameters:

  • interval_s — the period between latches (≥ 30 s recommended)
  • skip_stale=True (default) — stale snapshots are automatically skipped; the generator simply moves on to the next interval
  • skip_stale=False — stale snapshots are yielded with snap.valid=False, and the caller decides what to do with them

Full examples — examples_upy/05_async_streaming.py (MicroPython) and the asyncio equivalent in the CPython examples.


Scenario summary table

# LOC Runtime I²C bus Period? DRDY? MQTT? Persistence
1 ~25 both dedicated no no no no
2 ~35 both (OLED on uPy) shared with OLED (uPy) yes no no RAM
3 ~50 both shared 3 modules yes no no RAM
4 ~50 both dedicated yes no yes retained MQTT
5 ~40 both dedicated no (RT) no no RAM (master-owned)
6 ~60 both shared 3 modules yes no yes retained MQTT
7 ~40 both dedicated no (RT) no no RAM
8 ~30 CPython dedicated yes no no rotating-log file
9 ~50 MicroPython only dedicated yes no yes RTC memory + MQTT
10 ~25 both (asyncio/uasyncio) dedicated yes no (optional) RAM

Production deployment (CPython only)

For a long-running 24/7 deployment on a Linux SBC, a systemd service is recommended. A full example is in examples_cpython/10_systemd_service.py (it includes an --install helper that generates the /etc/systemd/system/rbamp.service unit file).

The basic structure:

python
# /usr/local/bin/rbamp_daemon.py
import sys, signal, time, logging
from smbus2 import SMBus
from rbamp import RbAmp, RbAmpSensorClass
logging.basicConfig(level=logging.INFO,
                    format="%(asctime)s %(levelname)s %(message)s")
log = logging.getLogger("rbamp")
shutdown = False
def on_signal(sig, frame):
    global shutdown
    log.info("Received signal %d, shutting down gracefully", sig)
    shutdown = True
signal.signal(signal.SIGTERM, on_signal)
signal.signal(signal.SIGINT,  on_signal)
with SMBus(1) as bus, RbAmp(bus, 0x50) as dev:
    log.info("rbAmp daemon started")
    while not shutdown:
        try:
            snap = dev.read_period_snapshot()
            log.info("P=%.1f W, Wh=%.4f", snap.avg_p[0], dev.energy.wh(0))
        except Exception as e:
            log.warning("snapshot failed: %s", e)
        time.sleep(60)
log.info("rbAmp daemon stopped")

And the unit itself:

ini
# /etc/systemd/system/rbamp.service
[Unit]
Description=rbAmp I2C AC sensor daemon
After=network.target
[Service]
Type=simple
ExecStart=/usr/local/bin/rbamp_daemon.py
Restart=on-failure
RestartSec=5
User=pi
[Install]
WantedBy=multi-user.target

Start it: sudo systemctl enable --now rbamp. Logs: journalctl -u rbamp -f.


What's next