Troubleshooting

This chapter is organized around the symptoms you actually see, not around an internal error taxonomy. If you're here, something isn't working right. Find your symptom in the list below, jump to the matching section, and follow the diagnostic procedure.

Most bench problems fall into three categories:

  1. Bus-level — the module doesn't answer over I²C, and reads raise RbAmpIOError.
  2. Data-level — the module answers, but the numbers are wrong: zeros, odd values, the wrong sign.
  3. Application-level — the link is unstable, the Wh counter drifts, or the script hangs / dies on a timeout.

Shortcut for the impatient: in steady state, the public methods should return values / yield snapshots without raising. If you see RbAmpIOError or RbAmpStaleError frequently in the logs, jump straight to the "Module doesn't answer over I²C" section below.


Module doesn't answer over I²C

What you see: dev.begin() (or entering the with RbAmp(bus, 0x50) as dev: context manager) raises RbAmpIOError or RbAmpVersionError, or RT reads regularly raise RbAmpIOError.

Step 1 — Bus scan

First, confirm the module is even present on the bus.

CPython (Linux SBC)

External tool:

sh
i2cdetect -y 1     # bus 1 — the standard one on the RPi 40-pin header

Or in Python:

python
from smbus2 import SMBus
with SMBus(1) as bus:
    print("Scanning...")
    for addr in range(0x08, 0x78):
        try:
            bus.write_quick(addr)
            print(f"Found 0x{addr:02X}")
        except OSError:
            pass

Expected output: Found 0x50 (or another address, if you changed it).

MicroPython

python
from machine import I2C, Pin
i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)
print("Found:", [hex(a) for a in i2c.scan()])

Expected output: Found: ['0x50'] (or your address).

What to do if nothing is found

It's a wiring or power problem:

  • SDA / SCL aren't swapped (see 04 · Hardware connection for per-host GPIO defaults).
  • Both lines have a pull-up to 3.3 V (the module board has built-in 4.7 kΩ resistors — no externals needed for a single module).
  • The module's supply pin really has 5 V on it (4.5–5.5 V).
  • No other master (debug probe, second controller) is hanging on the same lines.
  • On MicroPython, check that freq=50_000 (not 100k or 400k — on ESP32 with v1 firmware the baseline NACK pattern will eat your retry budget).
  • On CPython, check that the kernel I²C driver is loaded — lsmod | grep i2c_bcm on RPi.

What to do if the module shows up at an unexpected address

Someone re-addressed it earlier on the bench. Update the second argument to RbAmp:

python
dev = RbAmp(bus, 0x52)   # address from the bus scan

Step 2 — MicroPython + ESP32 baseline NACK pattern

If the bus scan finds the module but dev.read_voltage() occasionally raises RbAmpIOError — and you're on MicroPython + ESP32 — this is a documented baseline pattern: the I²C stack on the ESP32 port of MicroPython inherits quirks from the ESP-IDF v5 driver, which, when talking to rbAmp on the current firmware, produces a ~20 % NACK rate at 100 kHz.

The mitigation is already built into MachineI2CBackend (3 retries × 5 ms gap by default), but under heavy workloads the retry budget can run out.

What to do on ESP32:

  1. Lower the bus speed to 50 kHz:

python i2c = I2C(0, scl=Pin(22), sda=Pin(21), freq=50_000)

  1. Raise the retry count for a heavy workload — this needs the advanced API, by creating the backend explicitly:

```python from rbamp._io_micropython import MachineI2CBackend from rbamp import RbAmp

backend = MachineI2CBackend(i2c, retry_attempts=5, retry_gap_ms=5) dev = RbAmp(backend, 0x50) # the address goes to RbAmp, not to the backend ```

  1. Monitor the retry-exhaustion counter — it should stay zero in steady state:

python if backend.retry_exhaustion_count > 0: print("WARN: retry exhausted:", backend.retry_exhaustion_count)

Step 3 — Non-ESP32 platforms (RP2040 / STM32 / CPython)

On RP2040 / STM32 / Pyboard (via MicroPython) there is no baseline-NACK pattern — these platforms show a ~0 % NACK rate with rbAmp. MachineI2CBackend auto-detects the port and lowers the retry default to a single attempt.

On CPython (via smbus2) there is no retry layer at all — the Linux kernel I²C driver isn't subject to the NACK pattern; a single OSError from smbus2 is translated into RbAmpIOError with no retry.

If NACKs do occur on these platforms, look for:

  • High bus capacitance — long wires plus many devices. Lower the speed or shorten the cable.
  • Master contention — the package does not support multi-master.
  • Floating SCL between transactions — a missing pull-up.
  • On RPi: check dtparam=i2c_arm_baudrate in /boot/config.txt — 100000 is recommended.

Current reads zero on a working load

What you see: dev.current[0] (or dev.read_current(0)) returns 0.000 (or a very small value), even though a real consumer is on (a kettle, a lamp, an iron). dev.power_factor[0] may show an odd value (nan / 0 / ±1) — that's a side effect; the root cause is the current.

Diagnostic procedure

  1. Check that the sensor class and CT model are configured:

```python from rbamp import RbAmp, RbAmpSensorClass, RbAmpModeError

try: dev.set_sensor_class(RbAmpSensorClass.SCT_013) except RbAmpError as e: print("set_sensor_class failed:", e)

try: dev.set_ct_model(3) # or your model — see the table in 03 except RbAmpModeError: print("Class must be set first!") except ValueError: print("Code out of range 1..5") ```

On v1.2+ firmware, without these two calls the calibration coefficients aren't loaded, and current always reads as zero. This step is done once at first install — the choice is stored in the module's flash.

  1. Check that the CT model matches the load. A large CT clamp (for example SCT-013-100, 100 A) on a small load (a 50 W lamp = ~0.2 A) produces a signal right at the noise floor, and the readings will be zero. Pick the smallest CT model that covers your maximum expected current. The full table is in 03 · Current sensor selection.

If you have a multi-channel module (UI2 / UI3) and want to see both small loads and peak spikes, consider the dual-CT pattern: a small clamp (SCT-013-005) on one channel for the low range plus a large one (SCT-013-030/100) on another channel for the high range; the master picks the value by a threshold. The pattern is discussed in 03 · Current sensor selection, the "Dual-CT topology" section.

  1. Check the clamp orientation. The arrow on the clamp body should point in the direction of current flow toward the load. If the clamp is "backwards," dev.read_current() gives the right value in absolute terms, but dev.read_power() returns a negative value on a consuming load. Confirmation: dev.read_power_factor() will read exactly −1.0 on a resistive load (instead of +1.0). The fix is either to physically reinstall the clamp (unclip it, flip it so the arrow points correctly, clip it back) or to invert the sign on the application side (p = -p; pf = -pf; if you know the load isn't a PV inverter).

If all three steps pass but the current is still zero

Then the signal at the ADC really is below the noise floor. Check:

  • Whether current is actually flowing — measure with a multimeter (DC clamp / AC clamp meter) on the same wire.
  • Whether the clamp is intact — its connector should carry an AC voltage proportional to the current (a few millivolts for consumer loads).
  • Whether you're clamping the right wire — the line (phase) conductor, not the neutral (although a clamp on the neutral will also work — it measures current amplitude, not direction).

Readings jump around or raise RbAmpIOError

What you see: dev.voltage / dev.read_current(...) occasionally raises RbAmpIOError. The property value wasn't obtained — you need an application-side retry or a try/except guard.

RbAmpIOError from the package covers two classes of problem:

  • NACK after retry exhaustion — the link is unstable.
  • The sanity filter rejected a value — a float NaN / Inf / |x| > 10000 came off the bus (clearly not a physical value).

Tell them apart via the diagnostic counters (available on MicroPython):

python
from rbamp._io_micropython import MachineI2CBackend
# Created explicitly at the start of the program
backend = MachineI2CBackend(i2c, 0x50, retry_attempts=5)
dev = RbAmp(backend, 0x50)
# After a period of operation:
print("retries succeeded:", backend.retry_count_total)
print("retries exhausted:", backend.retry_exhaustion_count)
print("sanity rejects:",    dev.sanity_reject_count)
Counter What it means
retry_count_total ↑, retry_exhaustion_count = 0, sanity_reject_count = 0 Bus is healthy; the package quietly recovers the occasional NACK. Normal.
retry_count_total ↑, retry_exhaustion_count NACK plateau — increase retry_attempts (see Step 2 above).
retry_count_total low, sanity_reject_count The sanity filter is catching garbage after failed retries. Raise retry_attempts=5+.

On CPython (SMBusBackend) there is no retry layer — RbAmpIOError is raised on the very first failure. The symptoms are rare (the Linux kernel is usually reliable), but when they appear, check the wiring / pull-ups / bus speed.


Power Factor looks wrong

What you see: dev.power_factor[0] (or dev.read_power_factor(0)) returns a value that doesn't match the load type.

Expectations by load:

Load Expected PF
Kettle, iron, incandescent lamp +0.95 .. +1.0 (resistive)
Refrigerator, compressor motor +0.6 .. +0.85 (inductive)
LED lamp, TV (switch-mode PSU) +0.5 .. +0.95 (nonlinear)
PV inverter exporting power negative PF

PF = nan or 0 when I = 0

PF is defined as P / (U × I). At zero current I=0, the math is undefined. The exact value returned depends on the firmware (it may be nan, 0, or a placeholder) — that's normal as long as the current really is zero. Once current appears, a valid PF appears.

PF is exactly −1.0 on a purely consuming load

The clamp is installed "backwards" — the arrow points away from the direction of current flow to the load. The fix is either to reinstall the clamp correctly or to handle the sign on the application side (p = -p; pf = -pf; if you know the load can't be a PV inverter).

PF floats between +0.3 and +0.7 on a resistive load

  • Possible cause: the voltage reference is taken from a different phase. This applies to split-phase (240 V in the US) and 3-phase grids, where the module takes U from one phase while the CT clamp hangs on another — a 120° or 180° phase shift between U and I yields exactly these PF values. The fix is to install the module so the U input and the CT are on the same phase.
  • Alternative: the load really isn't purely resistive. Repeat the test with a known-resistive load (an electric kettle at full power).

Period snapshots are always RbAmpStaleError

What you see: dev.read_period_snapshot() raises RbAmpStaleError on every call. This means the module hasn't finished integrating the previous period by the time of the next read.

The package protects against double-counting Wh: on a stale read it records the master timestamp, so the next successful snapshot covers one period, not two.

Acceptable: rare stales (1–2 per hour at a 60 s cadence). Not acceptable: consecutive stales — that means the firmware is unresponsive or the master is polling too often.

Cadence-check procedure

  1. Check the cadence: 60 s between latches is comfortable; 30 s is marginal; < 10 s guarantees stales.
  2. Check the module's responsiveness between snapshots:

python if dev.probe(): print("alive")

  1. Check the flag directly:

python if dev.is_period_valid(): # safe to read avg_p[] ...

  1. Check the firmware versiondev.firmware_version >= 0x02 shows fewer stales than 0x01.

Special case — MicroPython deep-sleep wake

If you use a deep-sleep pattern on MicroPython, the default dev.read_period_snapshot() after a context-manager entry will always be stale (or give near-zero values) — __enter__ issues a priming LATCH that resets the firmware accumulator. The canonical pattern uses skip_latch=True plus a known sleep duration (the machine.deepsleep(SLEEP_MS) argument) — see 06 · Examples, Scenario 9.


Wh accounting drifts from a reference

What you see: dev.energy.wh(0), after several hours / days of operation, diverges from the utility meter or a reference meter (Kill-A-Watt, etc.).

First, rule out the trivial

  1. Current sensor calibration: confirm that dev.set_sensor_class() and dev.set_ct_model() were called with the correct CT model (see 03 · Current sensor selection). Without this, RMS current is computed against the default floor and the power value will be systematically biased.
  2. Dropped stale snapshots: if dev.energy.wh(0) is consistently below the reference, those may be missed intervals — the snapshot came back stale, the package protected against double-counting, but the interval measurement was lost. Check the cadence (see above).
  3. Master clock drift: time.monotonic() (CPython) and time.ticks_ms() (MicroPython) are reliable under normal operation. But if the master goes into deep sleep, use the RTC-memory + known-sleep-duration pattern from Scenario 9.

ticks_ms() wrap-around on MicroPython. time.ticks_ms() wraps at 2**30 ms (~12.4 days) — a naïve t1 - t0 subtraction across the 12.4-day boundary gives a negative / huge number. Internally the package uses time.ticks_diff(t1, t0), which is wrap-safe. If you compute master_dt_ms yourself in user code (outside the package), use ticks_diff, not raw subtraction.

Accumulator precision

The Wh accumulator inside the handle:

Runtime Type Long-term precision
CPython 64-bit float (Python float) drift < 1 LSB / year @ 60 s cadence
MicroPython (ESP32 N16R8 + double-precision build) 64-bit float same
MicroPython on ports without double-float 32-bit float ~0.01 % drift per day

Checking precision on MicroPython (sys.float_info exists only on CPython; on uPy we use an empirical check):

python
# On CPython:
import sys
print(sys.float_info.dig)   # 15 → double; 7 → single
# On MicroPython — empirically:
import sys
print(sys.implementation.name)   # 'micropython'
test = 1.0 + 1e-15
print("double" if test != 1.0 else "single")   # 1.0 + 1e-15 != 1.0 only on double

For single-float MicroPython ports on long soak installs, periodically call dev.energy.reset(0) and store the long-term total in your own persistent store (for example, via MQTT-retain in HA).


The script hangs / dies on a timeout

What you see: the Python script starts normally, then goes into a hang / RuntimeError after a few minutes.

CPython: signal.SIGTERM / KeyboardInterrupt not handled

Cause: a long time.sleep(60) blocks the signal handler. In a production deploy (systemd), systemctl stop rbamp waits for the SIGTERM response timeout (90 s default) and then kills via SIGKILL — Wh can be lost.

Fix: a signal-aware loop:

python
import signal, time
shutdown = False
def on_sig(sig, frame):
    global shutdown
    shutdown = True
signal.signal(signal.SIGTERM, on_sig)
signal.signal(signal.SIGINT,  on_sig)
while not shutdown:
    snap = dev.read_period_snapshot()
    # ... publish ...
    for _ in range(60):           # wake on the signal every second
        if shutdown: break
        time.sleep(1)

Or use asyncio with a signal_handler — see the section below.

MicroPython (ESP32): Watchdog timeout on WiFi connect

Cause: an unbounded WiFi connection loop trips the task-WDT after ~5 s (default).

Fix: a bounded wait with a restart fallback:

python
import network, time, machine
wlan = network.WLAN(network.STA_IF)
wlan.active(True)
wlan.connect("ssid", "pass")
t0 = time.ticks_ms()
while not wlan.isconnected():
    time.sleep_ms(100)
    if time.ticks_diff(time.ticks_ms(), t0) > 30_000:
        machine.reset()

The MQTT broker disconnects

On CPython (paho-mqtt): the default keepalive is 60 s, but mqtt.connect() is blocking and mqtt.loop() must be called in an event loop. Use mqtt.loop_start() (a background thread) or the asyncio variant aiomqtt.

On MicroPython (umqtt.simple): synchronous, with no keepalive — you have to call mqtt.ping() manually every ~30 s. The alternative is the async mqtt_as package with built-in keepalive.

TLS handshake fails (CPython cloud + RPi with little RAM)

Rarely a problem on 1+ GB RAM Pis, but on a Pi Zero / Zero W (512 MB) the large cert-store TLS handshake can get the process killed by the OOM killer.

Fix: - Use a specific CA instead of the system ca-certificates — less memory. - Reduce the MQTT buffers. - Move to a Pi 3/4/5 for a production cloud deploy.


set_sensor_class() / set_ct_model() raises RbAmpModeError

What you see: one of the setup calls raises RbAmpModeError with the message:

text
REG_SENSOR_CLASS is UNSET on v1.2+ firmware;
call dev.set_sensor_class(RbAmpSensorClass.SCT_013) first

Cause: on v1.2+ firmware, set_ct_model[_ch] requires that set_sensor_class() has been called before it. This is an intentional guard.

What to do:

python
from rbamp import RbAmpSensorClass
# Class first — MANDATORY
dev.set_sensor_class(RbAmpSensorClass.SCT_013)
# Then the model
dev.set_ct_model(3)   # or per-channel dev.set_ct_model_ch(ch, code)

More detail in 03 · Current sensor selection and 09 · API reference, the "Sensor configuration" section.

RbAmpModeError is also raised from prepare_address_change() / commit_address_change() when the module isn't in develop mode — a different situation, see the next item.


set_sensor_class() / set_ct_model*() raises RbAmpParamError or ValueError

What you see: the call raises RbAmpParamError (on CPython it also inherits ValueError through multi-base).

Possible causes:

  1. Invalid model code — the valid range is 1..5 (see the table in 03). Values 0 and 6+ raise RbAmpParamError(ValueError).
  2. Invalid channel index in the per-channel form dev.set_ct_model_ch(channel, code) — it must be < dev.channels.
  3. A reserved RbAmpSensorClass valueRbAmpSensorClass.WIRED_CT or BUILTIN_CT aren't supported yet (not present on the current SKU); use SCT_013.

set_ct_model_ch() raises RbAmpVersionError

What you see: the per-channel form raises RbAmpVersionError.

Cause: the module's firmware is too old for per-channel commands (the CMD_SET_CT_MODEL_CH0/1/2 opcodes appeared in v1.2). On v1.0 / v1.1 this command doesn't exist.

What to do:

  • Check the version: dev.firmware_version should return 0x03 or higher for the per-channel form.
  • Use the legacy single-arg form dev.set_ct_model(code) — it works on every firmware version, but only configures channel 0.
  • Update the module firmware to v1.2+ if you need full per-channel configuration.

prepare/commit_address_change() raises RbAmpModeError

What you see: the I²C-address-change methods raise RbAmpModeError.

Develop-mode-only operation. Changing the address requires the module to be in develop mode (an internal flag, set at the factory). On a standard production module this flag is not set, and these methods raise RbAmpModeError — that's expected behavior, not a bug. The dev.prepare_address_change() + dev.commit_address_change() method pair is intended for factory provisioning and integrator bench operations, not for user code. If a deployed module needs a different I²C address, the documented path is reconfiguration on the factory bench (outside the package's responsibility).

commit_address_change() raises RbAmpTimeoutError

If you have a module with develop mode enabled and prepare succeeded, but commit raises RbAmpTimeoutError, the "arming" window has expired (5 seconds after prepare). dev.probe() won't help here (the module answers; the problem is in the module's state machine). The fix is to call dev.prepare_address_change(new_addr) again and immediately, in the same function/iteration, with no network calls in between, call dev.commit_address_change(). Any blocking I/O between prepare and commit (WiFi, MQTT, HTTP) is the main cause of window expiry.

wait_ready() raises RbAmpTimeoutError

The module's ready bit wasn't set within timeout_ms. Possible causes:

  • The module hasn't finished its cold start yet (~250 ms) — increase timeout_ms or retry the call.
  • The module doesn't answer over I²C — see the "Module doesn't answer over I²C" section above.
  • The supply level dropped below 4.5 V — check VCC with a multimeter.

For more on the public-with-warning methods, see 09 · API reference, the "Sensor configuration" section (the address-change subsection lives there along with save_gains and factory_reset).


Exception summary table

RbAmpError (a subclass of OSError) is the base class. An existing except OSError: handler on the application side keeps catching rbAmp errors with no changes — the standard Python convention for hardware-I/O drivers.

Exception When Where to look
RbAmpIOError NACK after retry; sanity reject; bus-level failure "Module doesn't answer over I²C" section
RbAmpTimeoutError wait_ready() expired; the commit_address_change window (5 s) expired "commit_address_change raises RbAmpTimeoutError" section below
RbAmpNotReadyError (reserved; not raised in v1.1.0, exported for forward-compat) if you catch this type — repro it in an issue
RbAmpStaleError period snapshot stale "Period snapshots are always RbAmpStaleError" section
RbAmpParamError (on CPython also ValueError) bad argument: dev=None, ch out of range, code outside 1..5, a reserved cls. On v1.2+ also a precondition violation: set_ct_model*() without a preceding set_sensor_class() check the call arguments; on v1.2+ — that set_sensor_class() was called
RbAmpModeError develop mode not set for an address change "prepare_address_change / commit_address_change raises RbAmpModeError" section
RbAmpVersionError REG_VERSION = 0/0xFF on begin() (the module doesn't answer or the firmware is corrupt). Per-channel set_ct_model_ch on v1.0/v1.1 may NACK (the opcode doesn't exist) and raise RbAmpIOError, not RbAmpVersionError — the version guard is NOT implemented client-side; check dev.firmware_version ≥ 0x03 before calling check dev.firmware_version

Every exception has a __str__ with a meaningful message — the package carefully constructs error messages with context.


Diagnostic counters summary table

In a healthy soak run (the 1-hour long-soak harness) they all stay zero:

Counter Steady-state Reset Availability
dev.sanity_reject_count 0 dev.reset_counters() both runtimes
MachineI2CBackend.retry_exhaustion_count 0 backend.reset_counters() MicroPython only
MachineI2CBackend.retry_count_total low (~5-20 per hour is normal) backend.reset_counters() MicroPython only
stale fraction in period snapshots < 1 % (cumulative — no reset) both runtimes

If any of these is nonzero in steady state, go back to the matching section above.

The long-soak harness tests/test_long_soak.py runs via pytest libs/python/rbamp/tests/test_long_soak.py --soak --bus N --addr 0x50. For the six acceptance criteria, see the README.md "Long-soak regression harness" section.


Bus-level debug with a logic analyzer

For deep debugging, when the package can no longer tell you what's happening on the wire, capture SDA + SCL with a logic analyzer (Saleae, DSLogic Plus, Sigrok-compatible):

  • Sample rate ≥ 1 MS/s at 100 kHz I²C; ≥ 4 MS/s at 400 kHz.
  • The I²C decoder in Sigrok / Saleae will show ACK / NACK on each byte plus the address phase.
  • Compare your script's calls (dev.voltage, etc.) against the expected byte sequence — they should match exactly (single byte per address phase, no auto-increment).

If the package's behavior diverges from the capture, open an issue with the capture file attached (.sal / .dsl / .csv).


When to contact support

If you've worked through the matching section above and the problem persists, open an issue:

github.com/rb-amp/rbamp-python/issues

In the issue, include:

  • Runtime + version: python --version / mpremote eval 'import sys; print(sys.version, sys.implementation)'.
  • Host platform: "RPi 4B Bookworm", "ESP32-S3 N16R8 MicroPython 1.22", etc.
  • Package version: rbamp --version (CPython) or python -c "import rbamp; print(rbamp.__version__)".
  • Module firmware versiondev.firmware_version from the logs.
  • A minimal script (~30 LOC) that reproduces the problem.
  • The exception traceback with full context.
  • The counters at the time of failure: dev.sanity_reject_count, backend.retry_exhaustion_count (uPy only).
  • Verbose library logs — the easiest way to collect them is dev.set_logger(print) before the operation that fails. The package will print its internal steps (the retry loop, settle timeouts, the latch primer, and so on) — attach stdout to the issue.
  • (If you have one) a logic-analyzer capture file.

CLI — rbamp scan / rbamp read / rbamp address

The rbamp CLI is a thin wrapper over RbAmp.* for bench operations (see 09 · API reference, the "CLI" section). Because it uses the same RbAmp class, ALL the symptoms above apply. CLI-specific errors:

  • rbamp scan finds nothing — same as Step 1 in the "Module doesn't answer over I²C" section above. Check i2cdetect -y 1 directly. If it finds the module, it's a bug in our backend autodetect; open an issue with the output of rbamp --verbose scan.
  • rbamp <subcommand> fails with PermissionError: /dev/i2c-1 — the user isn't in the i2c group. See README § Installation for sudo usermod -aG i2c $USER plus a re-login.
  • rbamp: command not found after pip install — the [project.scripts] console entry isn't active. Check that pip show rbamp shows the installed location; make sure $HOME/.local/bin is on $PATH (for pip install --user).