Configuration, persistence and calibration


What survives what

Data Survives warm reset Survives power-off Survives firmware update How saved
Calibration (per channel, with its sensor) ✓ ✓ ✓ factory
Configuration (CFG_* flash rows) ✓ ✓ ✓ command 0x04 SAVE_CONFIG
Cumulative energy + generation ✓ (resumes from about the last publish window) ✓ (about the last second of energy lost on an ungraceful cut) ✓ automatic, every second (rules)
Hourly history + event log ✓ ✓ ✓ automatic
Boot counter ✓ ✓ ✓ automatic
Last 15-minute summary ✗ ✗ ✗ RAM only
CFG_RATE, CFG_HARM ✗ ✗ ✗ RAM only
EVENT_MASK, THRESH_I/P, PERIOD_ARM ✗ ✗ ✗ RAM — re-arm after any reset (DRDY)
Device clock ✗ ✗ ✗ master re-feeds time after every reset

Saving configuration

  1. Write the wanted CFG_* registers (list: register map).
  2. COMMAND = 0x04 (SAVE_CONFIG). The write is read-modify-write — calibration and the other config rows are untouched.
  3. Values are validated against one shared legal-value table before anything is written: an illegal value → ERROR 0xFD on I²C / exception 03 on Modbus, and nothing is persisted.
  4. Saves are rate-limited to about one per 5 s — a repeat answers 0xF9, retry later. A save with nothing changed is an OK no-op (it still raises the CONFIG_CHANGED event flag).
  5. When it takes effect: - after the next restart: CFG_I2C_ADDR, Modbus unit/baud/frame/tx-delay, CFG_VIRTUAL_IDS — save, then COMMAND 0x02 (on Modbus RESET is UNLOCK-gated); - immediately on write (but reverting at boot unless saved): CFG_LED, CFG_WORD_ORDER, CFG_START_UA (starting current); - stored values (labels, no effect on measurement): CFG_CLASS, CFG_CT_MODEL, CFG_TZ_OFFSET_MIN, CFG_TIME_AUTH, CFG_ENERGY_PERSIST_S.

Defaults after factory/fresh state: CFG_CLASS = 0 (unset), CFG_CT_MODEL = 0 (unset), CFG_TIER = 0 (regular), I²C 0x50, Modbus unit 1 / 9600 8N1 / ABCD, LEDs on. A master can tell an unconfigured module by the zeros.

Over Modbus the config rows are holding 0x8000–0x800C; SAVE_CONFIG itself is not UNLOCK-gated. Step-by-step: Sequences D3.


Calibration — the user-visible part

Every channel is calibrated at the factory together with its own current sensor; the pair is matched (sensors are labelled per channel) and the calibration is stored on the device. It survives resets, power loss and firmware updates. There is no user calibration procedure, and none is needed after installation.

What a user/master can do:

  • Read health: STATUS bit 0 (cal_ok): set when every channel carries a measured calibration, recorded by a marker stored with the calibration when it is saved. CAL_SRC (0x0872) says where the calibration came from: 1/2 = stored calibration · 0 = built-in defaults · 3 = the stored calibration does not match this firmware's measurement range — defaults in use. 0 or 3 means the module needs service — readings are uncalibrated.
  • Set metadata: CFG_CLASS (sensor class) and CFG_CT_MODEL (sensor model code) are reference metadata — they label what is connected for fleet inventory and do not change gains. Persist with SAVE_CONFIG.
  • Read the calibration blocks (CAL_V / CAL_I in the map) for audit — e.g. to verify two modules are not accidentally swapped with their sensors.

Writing the calibration blocks and SAVE_CAL (0x01) is a service/factory operation (UNLOCK-gated over Modbus; calibration saves are event-logged with a checksum). Incorrect values produce wrong readings with no warning — do not write these registers outside a service procedure.

The per-channel sensor pairing matters operationally: when moving a module, move its sensors with it, and keep each sensor on its labelled channel. A swapped sensor does not raise an error — the channel still measures, but to the other sensor's calibration.