I²C transport

The module is an I²C slave with the full register map. Default 7-bit address 0x50 (configurable, see below). recommended bus speed is 50 kHz on ESP32 and ESP8266 hosts and 100 kHz on other hosts (not 400 kHz); the slave supports clock stretching and a master must tolerate it (see limits below).

The active transport (I²C or Modbus RTU) is selected once per boot by the interface mode switch — see Hardware interface. On the I²C setting the Modbus register space is not served, and vice versa; commands and data are the same on both.


Register pointer

  • 16-bit register pointer, big-endian on the wire (high byte first), with auto-increment.
  • Write: master sends 2 pointer bytes (hi, lo), then a data stream; each data byte lands at the pointer, which post-increments.
  • Read: master writes the 2 pointer bytes, then issues a repeated start and reads; bytes stream from the pointer with auto-increment.
  • Multi-byte fields are little-endian and byte-addressed — no alignment requirement on the bus; a master may read any field as N little-endian bytes from its address, in one transaction or several.
  • Unmapped addresses: reads return 0xFF, writes are ignored. Channel-block addresses at index ≥ N_CURRENT / N_VOLTAGE are unspecified — gate on the counts, do not interpret them.

There is no bus-level probe for 8- vs 16-bit addressing (an 8-bit device would misread the second pointer byte as data). A master knows the convention by product line; the STD signature after a 16-bit read of 0x0000 is 'S','T' + VERSION ≥ 0x30 + CAPABILITIES bit 9.


Timing and robustness

  • Readiness after reset: the register interface comes up within milliseconds of a reset, before the measurement path — the module answers on the bus even while the sensor path is still starting. After a firmware activation reboot allow ~4 s before the device re-appears.
  • Clock stretching: normally negligible; during firmware-update flash operations the slave may hold SCL for up to ≈9 ms. Configure the master's SCL timeout to ≥10 ms or retries will be logged during OTA (data is not corrupted — the transaction simply waits).
  • During flash writes triggered by commands (saving configuration/calibration, OTA page programming) the slave may also not-acknowledge briefly. Retry until the command's settle time elapses rather than aborting on the first NACK (see Commands for settle times).
  • Coherency: every read transaction is served from a coherent 128-byte snapshot taken when the register address is set — fields read in one transaction of up to 128 bytes are from one publication and cannot tear (this is how to read i64 energy fields and whole blocks). Fields read in separate transactions may come from different windows. To detect a module restart between reads, check FRAME_CNT (0x0020) monotonicity and BOOT_COUNT (0x00CE).

Changing the I²C address

Two paths:

Direct (address known): 1. Write the new 7-bit address (0x08..0x77) to CFG_I2C_ADDR (0x0073). 2. COMMAND = 0x04 (SAVE_CONFIG) — validated; an illegal address is refused with ERROR 0xFD and nothing is persisted. Saves are rate-limited: a repeat within ~5 s answers 0xF9 — retry later. Wait for BUSY = 0 and ERROR = 0 before the next step. 3. COMMAND = 0x02 (RESET). The address applies on the reboot; the device re-enumerates at the new address in ~1 s.

⚠ After the reset every master on the bus must switch to the new address; plan this as an installation operation, not a routine one.

By UID (several modules on one default address): Write the target module's 12-byte UID to ADDR_UID (0x00E0), the new I²C address to ADDR_UID_I2C (0x00EC, 0 = keep) and/or the new Modbus unit id to ADDR_UID_UNIT (0x00ED, 0 = keep), then COMMAND = 0x16 (ADDR_BY_UID). Only the module whose UID matches persists the change — together with any other staged CFG_ values, like a SAVE_CONFIG — and restarts; every other module ignores the command (ERROR 0xFC there). Also accepted over a Modbus broadcast — see Modbus transport. Both new-address fields zero → 0xFD; illegal address → 0xFD; save rate limit → 0xF9. Step-by-step: Sequences D4.