Passa al contenuto

Energy meter 1 phase - STD-UI1

One voltage and one current channel. Counts import and export on the module.

Pick the sensor rating: 60 A or 100 A.

$ 19,90 $ 19,90

  • current
Termini e condizioni
Garanzia di rimborso di 30 giorni
Spedizione: 2-3 giorni lavorativi

available rbAmp Standard (STD)

For a single-phase input, a solar installation, a single machine, a small site.

Pick this if:

  • Export breaks my charts
  • The counter jumps after a reboot
  • I need a meter an inverter can read

Which rating? Pick the smallest kit rating above the circuit's maximum current: a 40 A main → 60 A; a 63 A main → 100 A. The sensors are calibrated with their channels — keep each sensor on the channel it is labelled for.

In the box

  • the meter in its DIN-clip enclosure
  • one current sensor, 60 A or 100 A as selected, calibrated with its channel and labelled

[[OPS: box contents and photo]]

Features

FeatureStatus
works without a master (Modbus RTU)available
import and export counters on the meter, saved every secondavailable
current in µA, energy in µWhavailable
I²C or Modbus RTU (three-position interface switch)available
13-point float profile compatible with the SDM630/SDM120 Modbus protocolavailable
eight snapshot banksavailable
hourly history: the last 7 records survive a restartavailable
update over the working bus with automatic rollbackavailable
signed and encrypted firmware imageavailable

The module has no RS-485 transceiver: the connector carries UART TTL and a driver-enable line for an external transceiver.

Measured characteristics per kit rating: see the table on the STD page.

SDM630, SDM120 and Eastron are names of a third-party manufacturer's meters, used only to state compatibility with their Modbus register protocol.

Installation and safety

STD-UI1 and STD-U3I3 are galvanically isolated: the connector side (VIN, GND, bus) is isolated from the mains measurement inputs. The board comes in an enclosure that covers the lower part with all mains circuits; the upper part with the interface connector is open and isolated; only the voltage-sensor terminal comes out, in a plastic housing. The enclosure has a DIN clip and can be installed in a cabinet.

  • one 7-pin interface connector: power, ground, bus, data-ready, driver enable, reset
  • voltage input: a thin wire is enough (AWG26–22); a fuse in the L line is mandatory, rated up to 0.1 A
  • sensors: the kit comes pre-connected; each sensor stays on the channel it is labelled for; follow the arrow for the import direction

STD is a sub-metering and monitoring instrument. It is not a utility settlement meter and makes no certification claims.

More: STD › Designed for electrical panel installation