STD-UI1
Single-phase energy meter for DIN rail
One voltage and one current input; kit with a 60 A or 100 A clamp.
STD energy meters
With solar on the roof, one total on the meter mixes what you bought with what you sold, and a counter kept in your controller starts over when it reboots. An STD meter counts import and export on the device itself and keeps the records, while the meter is powered — when the controller reboots, updates or disconnects.
Metering starts by itself at power-up; your controller sets the time and reads the data.

01 / Keeps counting
The meter measures, integrates energy and keeps separate import and export counters — on its own, saved every second. Your controller reads the accumulated values whenever it is there. When it reboots, updates or loses the link, the counters on the meter lose nothing: read them again when it is back. A power cut under load loses about a second of energy at most.
Autonomy of metering is not autonomy of power: the meter must stay powered to keep counting.
Source: Docs › STD › Energy and periods
02 / Models
Single-phase energy meter for DIN rail
One voltage and one current input; kit with a 60 A or 100 A clamp.
Three-phase energy meter for DIN rail
Three voltage and three current inputs; kit with 60 A or 100 A clamps.
03 / Counters
A single net figure cannot tell you how much came from the grid and how much went to it. STD keeps two independent counters for active energy — import and export — and two for reactive. They only grow, so import and export never cancel each other. Interval energy is the difference of two readings; a missed boundary merges two intervals and loses nothing.
STD-U3I3: the direction follows the balance of the three phases — the standard meter convention: a site exporting on one phase while importing on another is counted correctly.

04 / Records
Import and export, active and reactive; they never go down; journaled storage falls back to the last good copy.
The last 7 hourly records (energy and an electrical summary for each hour) survive a restart.
Eight independent banks: each consumer cuts its own period (a minute, 15 minutes, an hour) without disturbing the others.
Counter resets and adoptions, calibration saves and firmware updates, with before and after values.
The meter has no battery clock: your master sets the time after each restart. Counters run without it; hourly records are written once the time is set.
Source: Docs › STD › Energy and periods
05 / Resolution
Current is published in microamperes and energy is counted in microwatt-hours. This is the step of the numbers, not an accuracy claim.
Below a starting current (400 µA by default, configurable) a channel adds no energy, so an idle circuit does not creep. Readings are not affected.
Measured on production modules: current error within ±0.2 % from 5 mA to 75 A with the 60 A kit and from 5 mA to 100 A with the 100 A kit; readings start at about 5 mA.
What this means: a standby load that a coarse reading would bury in noise shows as a steady value — small currents are smoothed over a few seconds for a stable reading — and the start threshold keeps the counter still at zero.
06 / Measured
Measured on one production module per kit (60 A and 100 A), each channel individually calibrated together with its sensor, against a reference meter on a resistive load. Current is given as the primary current with one pass of the wire through the sensor; on STD-U3I3 the figures cover all three channels.
| Parameter | 60 A kit | 100 A kit |
|---|---|---|
| Class | ±0.2 % in range 0.005 A – 75 A | ±0.2 % in range 0.005 A – 100 A |
| Upper end of the range | 75 A | 129 A |
| Voltage error | ±0.2 % | ±0.2 % |
| Power factor, resistive load | 0.999–1.000 | 0.999–1.000 |
| Reads from | 4.8 mA | 4.8 mA |
| Noise with no current | 0.2 mA | 0.35 mA |
| Parameter | 60 A kit | 100 A kit |
|---|---|---|
| Current error | ±0.2 % in range 0.005 A – 75 A | ±0.2 % in range 0.005 A – 100 A |
| Upper end of the range | 75 A | 129 A |
| Voltage error | ±0.2 % | ±0.2 % |
| Power factor, resistive load | 0.999–1.000 | 0.999–1.000 |
| Reads from | 4.8 mA | 4.8 mA |
| Noise with no current | 0.2 mA | 0.35 mA |
07 / Interfaces
The full register map, the same client libraries as BASIC (the library detects the module at start), a data-ready output, one bus for STD and BASIC together — change the default address of one of them first.
The module has no RS-485 transceiver: the connector carries UART TTL and a driver-enable line for an external transceiver. The meter answers as a standalone Modbus device: a native integer map; a float32 register profile of 13 values (points outside the list read 0;
register map in the STD docs); per-channel virtual unit ids on STD-U3I3. Switch position «Modbus default»: 9600 8N1, unit 1. Frames 8N1 / 8E1 / 8O1 / 8N2, from 2400 baud.
The interface is chosen with a three-position switch — Modbus RTU · Modbus default · I²C — read at power-up; move it and restart to change. Modbus needs no library: any Modbus master reads the meter.
Source: Docs › STD › Hardware · Reference › Modbus
08 / Three-phase
STD-U3I3 is not three single-phase meters on one board. All six channels are sampled synchronously in one measurement window: per-phase voltage, current, power and power factor come from the same instant, and the totals are built from them. Energy direction follows the phase balance.
Before you trust per-phase readings, the meter reports the phase angles and whether the sequence is forward, reverse or abnormal — a wiring check built in.
Source: Docs › STD › STD-U3I3
Two firmware copies. The new image is written to the inactive copy over the working bus while metering continues. The image is signed and encrypted; a foreign, corrupted or older image is refused. A new image that does not confirm itself rolls back on its own.
Each meter carries a unique device certificate and answers a challenge from your master. Energy and log records are signed by the device, so records copied from another device or edited outside it are detected.
Saved every second, journaled, restored from the last good copy. If the storage becomes unavailable the meter keeps metering and recovers when it returns.
Status LEDs show metering and faults; an IDENTIFY command blinks them to find the meter in a cabinet.
10 / Safety
STD-UI1 and STD-U3I3 are galvanically isolated: the connector side (VIN, GND, bus) is isolated from the mains measurement inputs. The board comes in an enclosure that covers the lower part with all mains circuits; the upper part with the interface connector is open and isolated; only the voltage-sensor terminal comes out, in a plastic housing. The enclosure has a DIN clip and can be installed in a cabinet.
Safety. The measurement inputs connect to mains. For work inside an electrical panel, call a qualified electrician.
STD is a sub-metering and monitoring instrument. It is not a utility settlement meter and makes no certification claims.
Source: Docs › STD › Hardware
11 / Start
Clamp each sensor on its conductor, arrow toward the load; keep it on the channel it is labelled for. No sensor calibration required.
Choose I²C or Modbus on the interface switch, connect the bus and power the meter. Metering starts by itself.
Once after each power-up — there is no battery clock. Counters run even without it.
Live values about ten times a second, the counters, the records and the events.
Metering runs independently. After this your controller can go away and come back; the meter keeps counting while it is powered.
Source: Docs › STD › Quick start
12 / Uses
13 / System
STD takes the points where the numbers must be right — the grid input, the inverter, the charger. BASIC adds the branches — boiler, heat pump, lighting, workshop. One bus, one library, one controller: STD is the source of truth, BASIC fills in the picture. Start with one STD; add BASIC when you want the branches.
Main grid input — STD → branches — BASIC → ESP32 / Raspberry Pi / PLC
Source: Configure this set
14 / Specifications
Every line below is available.
| Measurement | synchronous sampling, about 3 kHz per channel · windows of whole mains cycles, a complete snapshot about ten times a second · per channel: RMS voltage and current, active power (signed), reactive and apparent power, power factor (signed), frequency · phase angles and phase sequence (STD-U3I3) · current in µA, energy in µWh · start threshold 400 µA by default, configurable |
|---|---|
| Energy and records | import and export, active and reactive · lifetime counters, journaled, saved every second · hourly history, last 7 records, survives a restart · eight snapshot banks · event log with before/after values · time set by the master (no battery clock) |
| Interfaces | I²C, 16-bit register map, address 0x50 by default · Modbus RTU from 2400 baud, 8N1 / 8E1 / 8O1 / 8N2, configurable word order · native register map · float32 register profile of 13 values · virtual unit ids (STD-U3I3) · discovery block · validated settings writes; reset, calibration and update need an explicit unlock · three-position interface switch, read at power-up · data-ready output · external RS-485 transceiver required (UART TTL + driver enable on the connector) |
| Update and identity | two firmware copies · signed and encrypted image · automatic rollback · older images refused · update over the working bus while metering continues · device certificate · signed records |
| Hardware | 7-pin connector · VIN 4.5–5.5 V, 30 mA typical, 50 mA max · 3.3 V logic · I²C pull-up jumpers on the board · two status LEDs, IDENTIFY · enclosure with DIN clip · voltage input fuse up to 0.1 A in each L line |
| Kit | current sensor per channel, 60 A or 100 A, calibrated with its channel and labelled |
| Measured characteristics | STD-UI1 and STD-U3I3 — above |
Single-phase and three-phase meters.
A pre-flashed ESP32 and a shield with connectors for the modules.
One contract, one library: the channel count is discovered at run time.
16 / Developers
Arduino · ESP-IDF · Python · ESPHome / Home Assistant — STD support: in validation until release. Modbus needs no library: any Modbus master reads the meter.
17 / Questions
No. It is a sub-metering and monitoring instrument and makes no certification claims; it is not for utility settlement.
Only to set the time and read the data. Metering starts by itself at power-up and keeps running while the meter is powered.
For a Modbus network, yes: the meter carries UART TTL and a driver-enable line for an external transceiver.
Energy is saved every second; a power cut under load loses about a second of energy at most. The counters continue from the last saved value.
The meter has no battery clock. Counters run without it; hourly records need it.
Yes, on one I²C bus with one library. Both answer at the same default address, so change the address of one of them before connecting both.
Yes. Move the interface switch and restart the meter; the switch is read at power-up.
The smallest rating above the circuit's maximum current. The sensors stay on the channels they are labelled for.
No. A microampere is the resolution — the smallest step of the numbers, not the accuracy. Current is read from about 5 mA. On production modules the measured current error is within ±0.2 % from 5 mA to 75 A with the 60 A kit and to 100 A with the 100 A kit. Full figures for the 60 A and 100 A kits: Measured characteristics and the docs.
Pick single-phase or three-phase; the meter counts import and export on its own, and your controller reads the totals when it is there.