Module Tiers


What a tier is

rbAmp ships in three tiers: BASIC, STANDARD, PRO. A tier is a complete bundle of hardware revision and firmware, not a software flag. Moving between tiers requires a physical change of SKU, not a firmware update.

From the perspective of the component and your application code: the rbamp_* API is identical across all tiers. The differences show up in which values the module returns and how the firmware's behavior interprets the data (in particular, export to the grid).


Current firmware state (v1.2)

Firmware v1.2 implements and ships only the BASIC tier. STANDARD and PRO are on the roadmap and are not implemented in the current firmware.

Tier Firmware Shipping
BASIC v1.2 ✅ yes
STANDARD planned for v1.3+ ❌ no
PRO planned for v1.3+ ❌ no

BASIC — the entry-level consumer-metering tier

Hardware

A cost-optimized analog signal path, suitable for typical residential loads. The module includes an isolated analog front-end, an on-board power regulator, and factory calibration stored in flash memory.

Firmware behavior

The logic of a classic mechanical disc meter — the count only moves forward; export to the grid is not subtracted.

The three "layers" of active-power values behave differently:

Signal Meaning Behavior on BASIC
rbamp_read_power(dev, ch, &p) instantaneous RT power, updated ~200 ms signed — a negative value is visible in real time (export)
snap.avg_p[ch] (inside rbamp_read_period_snapshot) average power over the period each 200 ms average-P window is clamped to max(P, 0) before being added to the period accumulator
rbamp_energy_wh(dev, ch) Wh accumulated by the component monotonic — consumption only; export is not counted

In other words: the user sees the export in the RT reading, but it is not present in the component's Wh counter on BASIC.

Typical applications

  • Households without their own generation (no solar panels, wind turbines, or battery systems)
  • Submeters for purely consuming loads (water heaters, motors, household appliances)
  • Building consumption monitoring where bidirectional metering is not required

Bidirectional metering on BASIC (master-side)

If you need to separately track export to the grid on a BASIC module, do it on the master side. The RT power rbamp_read_power(dev, 0, &p) is signed, so:

c
#include "esp_timer.h"
#include "freertos/FreeRTOS.h"
#include "freertos/task.h"
static double consume_wh = 0.0;
static double export_wh  = 0.0;
void bidirectional_loop(rbamp_handle_t dev) {
    int64_t t_prev_us = esp_timer_get_time();
    while (1) {
        /* Sample the RT power at 5 Hz — matches the firmware commit
         * cadence (200 ms per channel). Faster gives empty repeat
         * reads, slower loses resolution on sharp load transitions.
         * ±2 % accuracy is achievable for typical mixed loads with an
         * inverter. */
        vTaskDelay(pdMS_TO_TICKS(200));
        int64_t t_now_us = esp_timer_get_time();
        double  dt_s     = (double)(t_now_us - t_prev_us) / 1e6;
        t_prev_us = t_now_us;
        float p;
        if (rbamp_read_power(dev, 0, &p) != ESP_OK) continue;
        double dwh = (double)p * dt_s / 3600.0;
        if (p >= 0.0f) consume_wh += dwh;
        else           export_wh  += -dwh;
    }
}

A full working example of this pattern is in 06_examples.md, the "Bidirectional metering on the master side" scenario.


STANDARD — the bidirectional tier (planned, v1.3+)

This section describes planned functionality. It is not implemented in the current v1.2 firmware.

What will be added

  • Hardware: an extended analog stack for accurate measurement of both consumption and reverse flow
  • Firmware: bidirectional metering — two separate per-period accumulators (consumption and export), exposed separately through additional registers (details in the specification after the v1.3+ release)
  • Component API: rbamp_energy_wh(dev, ch) will start returning a signed net value (consumption − export) automatically, without master-side tricks

Typical applications (when it ships)

  • Homes with rooftop solar generation
  • Homes with wind turbines
  • Storage systems (batteries)
  • Regenerative loads
  • V2G (vehicle-to-grid) EV charging

PRO — the premium tier (planned, v1.3+)

This section describes planned functionality. It is not implemented in the current v1.2 firmware.

What PRO will add

  • Hardware: a PRO-grade analog front-end (lower noise, tighter linearity), premium factory calibration, optional extended channel sets
  • Firmware: bidirectional metering (like STANDARD) plus additional diagnostic features — details in the specification after the v1.3+ release
  • Component API: extended diagnostic accessors (the exact set will follow once it is implemented in firmware)

PRO applications (when it ships)

  • Submeters for commercial tenants
  • Billing-grade-accuracy installations
  • Test-and-measurement laboratories
  • Energy-intensive industrial loads

How to determine the tier at runtime

In firmware v1.2 there is no explicit "tier" register. Indirect indicators:

c
/* Firmware version — on v1.2 == 0x03 */
uint8_t fw = rbamp_firmware_version(dev);
/* Presence of a voltage sensor (UI* variants vs. I*-only) */
bool voltage_hw = rbamp_has_voltage_hw(dev);
/* Number of current channels (1 / 2 / 3) */
uint8_t channels = rbamp_channels(dev);

Note (v1.2): the indirect indicators above give different signals (firmware version, channel count, presence of a voltage sensor), but they do NOT give the tier — on v1.2 firmware the tier is implicitly always BASIC. Use the SKU label on the module's enclosure as the source of truth. An explicit tier register will be added in firmware v1.3+ when STANDARD starts shipping.


Where tier-dependent items are flagged in the docs

In the component text and the canonical documentation, tier-dependent features are flagged explicitly, for example:

STANDARD / PRO only — this register is not available on a BASIC module.

Or, conversely, BASIC-specific behavior:

BASIC: the rbamp_energy_wh(dev, ch) counter is monotonic — export to the grid is not counted. For bidirectional metering, see the "Bidirectional metering on the master side" scenario in 06_examples.md, or use a STANDARD/PRO module.


What's next