Solution · Standby and phantom loads

Everything is off and the meter still turns

The load that runs while nobody is home never shows up in a monthly total — it is the flat part of the bill that looks like the price went up. rbAmp STD resolves current in microamperes and keeps a configurable start threshold, so what is left running can be found instead of guessed at.

Why the bill never shows it

It is constant, so it hides

A load that runs all month is a flat offset. Averages hide offsets — that is what an average is for.

It is small, so it is rounded away

A handful of watts per device is nothing. Twenty of them, for 720 hours, is a line on the invoice.

It is invisible while you look

Switch things on and off during the day and the standby load is buried under the day. It is visible at night, which is when nobody is watching.

What makes a tiny load measurable

Three properties of the STD module, and one of them is a limit, not a feature.

  • Resolution: current in microamperes, energy in microwatt-hours. That is the step of the numbers.
  • A start threshold, 400 µA by default and configurable. Below it a channel adds no energy, so an idle circuit does not creep upwards from noise alone. Instantaneous readings are not affected — only the counter is held still.
  • Noise with no current: 0.2 mA on the 60 A kit, 0.35 mA on the 100 A kit — measured on production modules. This is the honest floor of "nothing is running".
  • ⚠️ Resolution is not accuracy. A microampere is the smallest step the numbers move in, not a claim about how right they are. Readings start at about 5 mA, and the measured current error — ±0.2 % — is specified over the range on the STD measured characteristics. Below that range a reading is an indication of something, not a measurement of how much.

Using BASIC instead? It will show the larger standing loads, and how small it can go depends entirely on the clamp's rating: see the per-rating table on /products/basic. A 100 A clamp cannot see a 5 W device, and no setting changes that.

How the hunt actually goes

  1. Measure the whole flat first, at night. One module on the input gives you the baseline — the number that should be near zero and is not.
  2. Halve the problem with the breakers. Switch off a group, watch the baseline drop or not. Two or three rounds and the group is found; this is why the reading has to be live and not a daily total.
  3. Then put a channel on the suspect group and leave it there overnight. A standby load has a signature: flat with periodic bumps, every few minutes, forever.
  4. Decide with the counter, not with the spec sheet. A device's standby rating and what it actually draws in your house are two different numbers, and only one of them is on your invoice.

STD modules → · Single-phase in the shop →

What to buy for this one job

One STD module, one controller, one clamp on the input is enough to get the baseline. The group-by-group hunt needs nothing more — the breakers do the dividing. Extra channels become useful afterwards, when the question changes from "what is running" to "how much does each group cost me".

Read before you buy

Find what is still running.

One module on the input, one night of data, and the flat part of the bill stops being a mystery.