Energy meter 3 phases - STD-U3I3

Three phases on one module: per-phase and total readings, phase-sequence check.

Neutral required — voltage terminal N, L1, L2, L3. Pick the sensor rating: 60 A or 100 A.

3-phases
$ 59,90 $ 59,90

  • current
Conditions générales
Garantie satisfait ou remboursé de 30 jours
Livraison : 2-3 jours ouvrables

available rbAmp Standard (STD)

For a three-phase input, a workshop or production floor, a charging site, a three-phase solar system.

Neutral required — voltage terminal N, L1, L2, L3.

Pick this if:

  • Three-phase input of a building or workshop
  • A meter per tenant
  • Three-phase metering per charger

Which rating? Pick the smallest kit rating above the circuit's maximum current: a 40 A main → 60 A; a 63 A main → 100 A. The sensors are calibrated with their channels — keep each sensor on the channel it is labelled for.

In the box

  • the meter in its DIN-clip enclosure
  • three current sensors, 60 A or 100 A as selected, calibrated with their channels and labelled

[[OPS: box contents and photo]]

Features

FeatureStatus
works without a master (Modbus RTU)available
3 voltage + 3 current channels, sampled synchronouslyavailable
per-phase and total readingsavailable
import and export by the phase balance — the standard meter conventionavailable
phase angles and phase-sequence checkavailable
energy counters per current channelavailable
virtual unit ids: on Modbus each current channel also answers as its own read-only single-phase view (voltage, current, power)available
all STD features of STD-UI1: counters saved every second, snapshot banks, hourly history, update with rollbackavailable

The module has no RS-485 transceiver: the connector carries UART TTL and a driver-enable line for an external transceiver.

Measured characteristics per kit rating: see the table on the STD page.

SDM630, SDM120 and Eastron are names of a third-party manufacturer's meters, used only to state compatibility with their Modbus register protocol.

Installation and safety

STD-UI1 and STD-U3I3 are galvanically isolated: the connector side (VIN, GND, bus) is isolated from the mains measurement inputs. The board comes in an enclosure that covers the lower part with all mains circuits; the upper part with the interface connector is open and isolated; only the voltage-sensor terminal comes out, in a plastic housing. The enclosure has a DIN clip and can be installed in a cabinet.

  • one 7-pin interface connector: power, ground, bus, data-ready, driver enable, reset
  • voltage input: a thin wire is enough (AWG26–22); a fuse in the L line is mandatory, rated up to 0.1 A
  • voltage terminal N, L1, L2, L3 — neutral required; fuse each L line
  • sensors: the kit comes pre-connected; each sensor stays on the channel it is labelled for; follow the arrow for the import direction

STD is a sub-metering and monitoring instrument. It is not a utility settlement meter and makes no certification claims.

More: STD › Designed for electrical panel installation