06 · Energy and periods

How to get energy from an STD module: cumulative counters, hourly history, the event log, and the eight snapshot banks. Full rules: Measurement & energy model.


Cumulative counters

The module keeps life-time energy counters that survive power-off: active import, export and net in Wh, mWh and µWh; reactive import and export in varh and µvarh. Read them in one transaction over 0x0800–0x0843 (and 0x08D0–0x08F7 for the fine-resolution set).

Rules:

  • Read energy from the module; never integrate P·dt on the host. The module's integral is gap-compensated and survives restarts.
  • Interval energy = the difference of two readings at the interval boundaries. A missed boundary merges two intervals and loses nothing.
  • After a restart the counters continue from the last saved value; up to about the last second of energy may be missing. Take the difference as max(0, new − last) and re-anchor — do not discard the period.
  • LT_GEN (0x0840) steps on every counter reset or adopt. If it changed, do not take the difference: re-anchor and check the event log.
  • Starting current (CFG_START_UA, default 400 µA): below it a channel adds no energy to any counter, which stops no-load creep. Readings are not affected.

Hourly history

The module keeps the last 7 hourly records (energy and an electrical summary for each hour) in non-volatile memory (HIST_CAP, 0x0C08, gives the number of records). The records survive a restart; a longer archive is kept by the master.

  • Records are written only after the master has set the time, and the master sets it again after every module restart: there is no battery-backed clock (see Getting started).
  • A record closes when the module's clock passes the hour boundary. A part-hour record (the time was set mid-hour, or the module powered up mid-hour) carries a flag.
  • Of the 15-minute period only the last finished summary is available (electrical values, no energy). It is kept in RAM and is lost on restart.

Query interface: register map.


Event log

The event log holds counter resets and adopts, calibration saves, firmware updates and rejected records, with before/after values; drain it periodically.


Snapshot banks

When CAPABILITIES bit 8 = 1, the module has eight independent snapshot banks: every master freezes the period it needs, and several consumers do not disturb one another. Use them when several modules must cut the same period at the same instant; for one module the counter differences above are simpler.

  1. Arm. Write PERIOD_ARM (0x0063): bit b = 1 makes bank b accumulate. A newly armed bank starts empty.
  2. Snapshot. Write LATCH_BANK (0x0062) = b, then command 0x03 (LATCH_PERIOD). The cut is taken at the next window boundary; the bank restarts from zero. On a Modbus bus the same writes may be sent on broadcast (unit 0) for one cut across modules.
  3. Wait. After CMD_SEQ steps, wait until WIN_SEQ has advanced by 2 (about 200 ms).
  4. Read. The bank is at 0x2000 + b·0x800 (Modbus input 0x7000 + b·0x100): P / Q / S averaged over the period, signed energy, window count, peaks, and per-channel energy. PD_VALID bit b says the bank holds a snapshot; it stays set and is not a freshness flag.

Banks are RAM: a reset clears them. A bank snapshotted during the first 3 windows after boot holds zeros with WIN_CNT = 0. Layout and units: register map.


In the client libraries

In the client libraries — the same task without register access:

Library Call What it does
Arduino stdArmBanks, stdLatch, stdReadLatch, stdLatchWh arm banks, take a snapshot, read it and convert it to Wh; available when the module reports banks (bit 8)
ESP-IDF rbamp_std_arm_banks, rbamp_std_latch, rbamp_std_read_latch, rbamp_std_latch_wh the same in the ESP-IDF component; bank 0 belongs to the library, use banks 1 and up (example std_meter)

See Examples.